Summary of Contents for Daikin Altherma EAVZ16S23DA6V
Page 1
User reference guide Daikin Altherma – Low temperature split EAVZ16S18DA6V EAVZ16S23DA6V User reference guide EAVZ16S18DA9W English Daikin Altherma – Low temperature split EAVZ16S23DA9W...
▪ This appliance can be used by children aged from 8 years and commissioning................18 above and persons with reduced physical, sensory or mental 8 Relocation capabilities or lack of experience and knowledge if they have been User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
▪ Do NOT place any objects containing water on the unit. Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. NOTICE The original documentation is written in English. All other languages ▪...
▪ Installer: 1 h Home screen Main menu screen Dials and buttons Lower level screens: c1: Setpoint screen You use the dials and buttons: c2: Detailed screen with values User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
Shows the applicable symbol for your additional g3 Room thermostat type: zone emitter type. ▪ : Daikin user interface used as room Set the leaving water temperature for the thermostat additional zone (if present). ▪ : External control Shows the applicable symbol for your unit.
Change the value. This unit is a heating only model. The system can heat up a space, Go to the next setting. but NOT cool down a space. User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
Heat emitter of the main zone blue pulsation with an interval of approximately 5 seconds. Heat emitter of the additional zone (if any) Room thermostat type of the main zone EAVZ16S18+23DA6V+9W User reference guide Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
▪ The desired leaving water temperature will return to its scheduled value whenever a scheduled action occurs. You can avoid scheduled behaviour by (temporarily) turning off scheduling. User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
Advanced user pin code 00:00 07:00 14:00 21:00 The Advanced user pin code is 1234. Additional menu items for the DHW tank temperature Time user are now visible. EAVZ16S18+23DA6V+9W User reference guide Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
While holiday mode is active, space heating operation and domestic hot water operation will be turned off. Room frost protection and anti-legionella operation will remain active. User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
2 Select the correct electricity price. Calculation of the electricity price: 3 Confirm the changes. Electricity price=Actual electricity price+Incentive/kWh 4 Repeat this for all three electricity prices. — Electricity price=12.49+5 Electricity price=17.49 EAVZ16S18+23DA6V+9W User reference guide Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
To program the schedule 6:00 20°C 22:00 18°C Example: You want to program the following schedule: 8:30 18°C --:-- 17:30 21°C User defined 1 4 Confirm the changes. User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
--:-- and [2.6] for the main zone and [3.5] and [3.6] for the additional zone, see below. 4 Confirm the changes. 5 Select Saturday. 6 Select Copy. EAVZ16S18+23DA6V+9W User reference guide Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
The symbol shown here corresponds to the heat emitter for that zone: ▪ : Underfloor heating ▪ : Fan coil unit ▪ : Radiator ▪ : Domestic hot water tank User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
Operation Room Space heating/cooling Tank Setpoint screen Only applicable when EKHVCONV2 is installed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EAVZ16S18+23DA6V+9W User reference guide Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
The refrigerant inside this unit is mildly flammable. temperature and do NOT let the room temperature drop too low. It will take more time and energy to heat up the room again. User reference guide EAVZ16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...
1 Go to [8.2]: Information > Malfunction history. Heat pump is damaged. "7.1 To display the help text You see a list of the most recent malfunctions. in case of a malfunction" on page 17. EAVZ16S18+23DA6V+9W User reference guide Daikin Altherma – Low temperature split 4P556076-1 – 2018.10...