5.2.3 Configuration wizard: System ........15 Daikin website (publicly accessible). 5.2.4 Configuration wizard: Backup heater ......16 ▪ The full set of latest technical data is available on the Daikin 5.2.5 Configuration wizard: Main zone......... 16 extranet (authentication required). 5.2.6 Configuration wizard: Additional zone......
See the installer reference guide for more information. ▪ Space heating operation: 5~30°C Minimum required flow rate ▪ Space cooling operation: 5~35°C 20 l/min ▪ Domestic hot water production: 5~35°C Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Backup heater Power supply Required number of type conductors 1N~ 230 V (6V) 2+GND 3~ 230 V (6T1) 3+GND 3N~ 400 V 4+GND EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Prerequisite: The user interface panel and front panel have been removed. 1 Remove the top panel that keeps the switch box into place at the top of the unit. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Outdoor unit water connection in NOTICE It is recommended to install shut-off valves to domestic cold water in and domestic hot water out connections. These shut-off valves are field supplied. EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Ethylene glycol is toxic. functions such as water pipe freeze prevention and drain prevention (see installer reference guide) that include the activation of pump in case of low temperatures. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Factory-mounted cable for power supply of backup heater 3 Routing of the wiring inside the unit should be as follows. Fix the cable to the cable rail using cable ties: EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
It is only possible for the system to have EITHER preferential kWh rate power supply OR a safety thermostat. 4.4.3 To connect the main power supply 1 Connect the main power supply. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
2 Fix the cable with cable ties to the cable tie mountings. 4.4.8 To connect the alarm output 1 Connect the alarm output cable to the appropriate terminals as shown in the illustration below. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
▪ What you can see on and do with the user interface 2 Fix the cable with cable ties to the cable tie mountings. You can configure the system via the user interface. EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Code Description To access the installer settings [7.2] Set the local time and date 1 Set the user permission level to Installer. 2 Go to [9]: Installer settings. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
[2.7] and for the additional zone [3.7] correctly in heating screed dryout function, and the water pipe accordance with the connected emitter. antifreeze function will remain active even if the user does NOT confirm emergency operation. EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
50°C, water temperature regardless the actual room Daikin recommends NOT to disable the backup heater temperature and/or heating or cooling demand second step because it will have a big impact on the of the room.
▪ 0: Leaving water if the control type of the main zone is Leaving water. ▪ 1: External room thermostat if the control type of the main zone is External room thermostat or Room thermostat. EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
You can set additional settings using the main menu screen and its submenus. The most important settings are presented here. 5.3.1 Main zone Thermostat type Only applicable in external room thermostat control. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
1 Set the user permission level to Installer. See "To — change the user permission level" on page 14. The air purge valve is open (at least 2 turns). 2 Go to [A.1]: Commissioning > Operation test run. Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
▪ Explain the user about energy saving tips as described in the ▪ Shut off valve test operation manual. ▪ Diverter valve test ▪ Bivalent signal test ▪ Alarm output test ▪ C/H signal test ▪ DHW pump test EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
8 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). Piping diagram: Indoor unit...
Normal kWh rate power supply Normal kWh rate power supply Position in switch box Position in switch box Only for normal power supply Only for normal power supply (standard) (standard) EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Page 24
Only for wireless On/OFF Normally open Normally open thermostat thermostat Safety thermostat contact: 16 V Safety thermostat contact: DC detection (voltage supplied 16 V DC detection (voltage by PCB) supplied by PCB) Installation manual EAVH/X16S18+23DA6V+9W Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...
Page 25
A8P: X801M: 4-5 demand input 4 signal 2 core Only for EKRUDAS 2x0.75 X5M: 11-12 A14P: P1-P2 user interface communication 2 core 2x0.75 A13P: P1-P2 LAN adapter communication 4D120625 EAVH/X16S18+23DA6V+9W Installation manual Daikin Altherma – Low temperature split 4P556067-1 – 2018.10...