Installation
4 4 .2.6

Do a check on the gas connections

4.2.7

Make the electrical connection

1.
2.
4.2.8

Connect the concentric flue system

1.
2.
4.2.9

Install the flue gas restriction plate

Safety conditions
Procedure
1.
2.
4.2.10

Remove the baffle plate

The appliance is factory supplied with a baffle plate. This baffle plate is located at the top
of the combustion chamber, just before the connection with the concentric flue. The baffle
plate only remains on location, if a restriction plate needs to be mounted. Refer
24
Make sure that the gas connections do not leak. Use soapy water or a leak tester.
Caution:
Use a wall socket with earth connection.
The socket must be accessible at all times.
Connect the plug to the wall socket.
Make sure that the electrical cable does not touch the appliance, due to the high
temperatures of the appliance.
Connect the concentric flue system to the appliance. Use the materials that are
specified in the preparation manual. Do not use any other materials.
Make sure that all mechanical connections of the concentric flue system are correctly
connected.
Caution:
Install the correct restriction plate. An incorrect restriction plate can cause
damage to the appliance.
Remove the glass. See
Install the restriction plate (A) with
the fasteners (B) in the appliance.
Use the restriction plate specified in
the preparation manual. Baffle plate
(C) stays in place when a restriction
plate must be installed.
5.2.1
.
4.2.9
.
Box Gas Panorama 73/52