Format: F0 00 20 0D 32 (bank no. / dev ID) 10 F7 This string triggers a complete dump of all value
response data bytes including the level meter data.
Set Value
Sets any number of parameters. nn / oo can be repeated freely.
Value Response
After being triggered by receiving a request value command, device sends a string of all value response
data bytes. Message type is set to 30h.

12.1.3. Table

No.
No
Name
.
00h
0
settings byte 1
01h
1
settings byte 2
02h
2
settings byte 3
03h
3
info byte 1
04h
4
info byte 2
05h
5
info byte 3
06h
6
info byte 4
07h
7
level ch 01
08h
8
level ch 02
09h
9
level ch 03
0Ah
10
level ch 04
0Bh
11
level ch 05
0Ch
12
level ch 06
0Dh
13
level ch 07
0Eh
14
level ch 08
0Fh
15
level ch 09
10h
16
level ch 10
11h
17
level ch 11
12h
18
level ch 12
13h
19
level ch 13
14h
20
level ch 14
15h
21
level ch 15
16h
22
level ch 16
17h
23
level ch 17
RME M-32 AD Pro User's Guide
Set
Val.
Data bytes
Val.
Resp
.
x
x
hex coded value of byte (see below)
x
x
hex coded value of byte (see below)
x
x
hex coded value of byte (see below)
 
x
hex coded value of byte (see below)
 
x
hex coded value of byte (see below)
 
x
hex coded value of byte (see below)
 
x
hex coded value of byte (see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
 
x
(see below)
12.1. MIDI Implementation Chart | 51