  • Page 1 EdgeMarc 4800 Hardware Installation Guide U.S. Headquarters: Edgewater Networks, Inc. 5225 Hellyer Ave. #100 San Jose, California 95138 Phone: 408.351.7200 Fax: 408.727.6430 edgewaternetworks.com...
  • Page 2 No part of this document may be reproduced in any form by any means without prior written authorization of Edgewater Networks, Inc. Documentation is provided “as is” without warranty of any kind, either express or implied, including any kind of implied or express warranty of non-infringement of the implied warranties of merchantability or fitness for a particular purpose.
  • Page 3: Table Of Contents

    EdgeMarc 4800 Front Panel......5 EdgeMarc 4800 Back Panel ......7 Ethernet Port LEDs.
  • Page 4 Limitation of Liability ......37 Support and Services Agreements ....37 © 2016 Edgewater Networks. All Rights Reserved.
  • Page 5: About This Guide

    For instructions on using the EdgeMarc VoIP Operation System (VOS) web-based GUI to configure, deploy, and manage the EdgeMarc, refer to the EdgeMarc VOS User Guide in the Edgewater Networks Knowledgebase: www.edgewaternetworks.com/kb Typographic Conventions...
  • Page 6: Document Organization

    Contact and Support Information Headquarters 5225 Hellyer Ave., #100 San Jose, CA 95138 (408) 351-7200 Fax: 408.727.6430 General: info@edgewaternetworks.com Sales: sales@edgewaternetworks.com Edgewater Networks, Inc. - Technical Assistance Center Phone: 408.351.7200 ext. 2 support@edgewaternetworks.com © 2016 Edgewater Networks. All Rights Reserved.
  • Page 7: Product Overview

    The EdgeMarc 4800 provides superior performance for simultaneous services including voice, voice quality monitoring, traffic management, high capacity data throughput and firewall. EdgeMarc 4800 Front Panel The two LEDs on the EdgeMarc 4800 front panel indicate the power status and the data status (Figure 1-1).
  • Page 8 The device is loading the EdgeMarc VoIP Operation System Green (VOS). Solid VOS is ready. Green The device is in the bootloader. The kernel will change the LED to solid amber once the kernel starts loading. © 2016 Edgewater Networks. All Rights Reserved.
  • Page 9: Edgemarc 4800 Back Panel

    2 x 10/100/1000 Mbps RJ-45 Ethernet ports for WAN network connectivity (copper). The EdgeMarc 4800 supports dual WAN port capability for added flexibility. Dual WAN port functionality is configured on the EdgeMarc 4800 WAN Port 1 and WAN Port 2. WAN Fiber/Link Status Fiber port support 1Gb link: Access LEDs Solid green LED indicates peer link is powered.
  • Page 10 EdgeMarc 4800 Hardware Installation Guide Table 1-2 EdgeMarc 4800 Back Panel Components (continued) SD Card Storage Allows the EdgeMarc to save configurations and other files to an SD High Capacity (SDHC) Version 2.0 card. Interface Maximum storage capacity is 32 GB per SD card, 4 GB per file.
  • Page 11: Ethernet Port Leds

    On—Solid A powered device is connected and the port speed is set to Green 100 Mbps. The device is not powered, no cable connected, or the port speed is set to 10 Mbps. © 2016 Edgewater Networks. All Rights Reserved.
  • Page 12: Edgemarc 4800 Side Panels

    EdgeMarc 4800 Hardware Installation Guide EdgeMarc 4800 Side Panels The EdgeMarc 4800 is equipped with physical security locks located on the side panels of the device. Refer to Figure 1-3 Figure 1-4. Figure 1-3 EdgeMarc 4800 Right Side Panel Security Lock...
  • Page 13: Serial Craft Console Port Cable

    Product Overview Serial Craft Console Port Cable The EdgeMarc 4800 uses a single DB9 female to DB9 male serial straight through cable, as shown in Figure 1-5. This cable is not included in the box with the EdgeMarc 4800. Figure 1-5...
  • Page 14 The FTP file server is used for endpoint configuration file storage. Remote access SSH into the EdgeMarc 4800 via SCP for remote access to the SD card and files within the SD card. System alerts for A system alert is issued when an SD card is SD card inserted or removed.
  • Page 15: Physical Installation

    Connecting the Power and Cables  Overview The EdgeMarc 4800 appliance is designed for desktop, wall, shelf, tray, or rack installation. Observe the following guidelines when installing the system: Always verify that the AC power cord is disconnected from a power ...
  • Page 16: Edgemarc 4800 Appliance Shipping Contents

    EdgeMarc 4800 Hardware Installation Guide EdgeMarc 4800 Appliance Shipping Contents The EdgeMarc 4800 ships with the contents pictured in Figure 2-7. Figure 2-7 EdgeMarc 4800 Box Contents Table 2-5 describes the components that are shipped with the EdgeMarc 4800 appliance.
  • Page 17: Required Tools And Materials

    EdgeMarc units are designed with a robust internal surge protection system. For surge protection to function during all events, the EdgeMarc 4800 supplemental ground (the AC power cord) must be connected with a low impedance conductor directly to the same ground point as the service providers’...
  • Page 18: Grounding The Edgemarc 4800

    EdgeMarc 4800 Hardware Installation Guide Note Note Note The EdgeMarc 4800 appliance has an internal power supply with a grounded power cord that must be connected to a properly grounded power outlet. Grounding the EdgeMarc 4800 The EdgeMarc 4800 has an external earth ground connection. Refer to...
  • Page 19 Mount the device with the front panel placed horizontally facing up or down on the wall, as shown below. Caution Caution Caution Do not mount the device with the front panel placed vertically facing left or right, as shown below. © 2016 Edgewater Networks. All Rights Reserved.
  • Page 20: Installing The Edgemarc 4800 In A Rack

    EdgeMarc 4800 Hardware Installation Guide Installing the EdgeMarc 4800 in a Rack Install the EdgeMarc in a 19” rack using the rack mount kit supplied with the device. Before You Begin Before installing the EdgeMarc in a rack, take note of the following conditions: Elevated Operating Ambient—If installed in a closed or multi-unit rack...
  • Page 21: Connecting The Power And Cables

    Connect the EdgeMarc to ground. See Grounding the EdgeMarc 4800. Connecting the Power and Cables The EdgeMarc 4800 comes with an AC power cord for connecting the AC power brick to an AC outlet. Warning Warning Always connect the AC power cord to an AC outlet suitable for the power supply that came with the unit to reduce the risk of damage.
  • Page 22 EdgeMarc 4800 Hardware Installation Guide © 2016 Edgewater Networks. All Rights Reserved.
  • Page 23: Configuring Basic Network Settings

    EdgeMarc device for your network deployment. Connecting to the EdgeMarc for the First Time  Deploying the EdgeMarc 4800 Session Border Controller  Connecting to the EdgeMarc for the First Time The LAN interface ports are pre-configured with the IP address 192.168.1.1.
  • Page 24 (Figure 3-8). Figure 3-8 Change Password Page Enter password information as described in red in the login window and follow system prompts to log in to the EdgeMarc Admin landing page (Figure 3-9). © 2016 Edgewater Networks. All Rights Reserved.
  • Page 25: Deploying The Edgemarc 4800 Session Border Controller

    Configuring Basic Network Settings Figure 3-9 EdgeMarc Admin Landing Page Deploying the EdgeMarc 4800 Session Border Controller The EdgeMarc is deployed as a Session Border Controller on the network. For details about how to configure and deploy the EdgeMarc device in your...
  • Page 26 EdgeMarc 4800 Hardware Installation Guide © 2016 Edgewater Networks. All Rights Reserved.
  • Page 27: A Safety, Compliance, And Certifications

    Agency Label—4800 Certifications RoHS Compliant, WEEE Compliant Safety UL/cUL, LVD, Gost-R, Mexico CoC, UL-AR Emissions FCC Part 15 Class A, ICES-003, VCCI Class A, KCC, CCC, C-tick, BSMI, ANATEL Immunity MTBF 96,000 (hrs) © 2016 Edgewater Networks. All Rights Reserved.
  • Page 28: Usa And Canadian Notices

    In accordance with Part 15 of the FCC rules, the user is cautioned that any changes or modifications not expressly approved by Edgewater Networks, Inc. could void the user's authority to operate this equipment. The socket outlet to which this apparatus is connected must be installed near the equipment and must always be readily accessible.
  • Page 29 In most, but not all areas, the sum of RENs of all devices that may be connected to a line, is determined by the total RENs, contact the local telephone company. © 2016 Edgewater Networks. All Rights Reserved.
  • Page 30: Canadian Certification Requirements For Bilingual Safety, Warning And Caution Markings

    This document applies to all customers of ULs product certification services for the Canadian markets, for example, UL/C-UL/ULC Mark certifications. View the Canadian Certification Requirements for Bilingual Safety, Warning and Caution Markings document. © 2016 Edgewater Networks. All Rights Reserved.
  • Page 31: Class A Statements

    Hereby, Edgewater Networks, declares that this EdgeMarc 4800 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Česky Edgewater Networks tímto prohlašuje, že tento EdgeMarc 4800 je ve shodě [Czech]: se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
  • Page 32 Edgewater Networks declara que este EdgeMarc 4800 está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. [Portuguese] Slovensko Edgewater Networks izjavlja, da je ta EdgeMarc 4800 v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. [Slovenian]: © 2016 Edgewater Networks. All Rights Reserved.
  • Page 33: Restriction Of Hazardous Substances Directive (Rohs)

    överensstämmelse med de väsentliga egenskapskrav och övriga relevanta [Swedish]: bestämmelser som framgår av direktiv 1999/5/EG. Íslenska Hér með lýsir Edgewater Networks yfir því að EdgeMarc 4800 er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC (Icelandic): Norsk Edgewater Networks erklærer herved at utstyret EdgeMarc 4800 er i...
  • Page 34: Important Safety Instructions

    évier, d’un lavabo ou d’une machine à laver, dans un sous-sol humide ou près d’une piscine. Evitez d’utiliser un téléphone (autre qu’un sans fil) durant un orage. Il y  a un risque de choc électrique à distance depuis un éclair. © 2016 Edgewater Networks. All Rights Reserved.
  • Page 35: Rack Mount Instructions

    Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Earthing—Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply © 2016 Edgewater Networks. All Rights Reserved.
  • Page 36: Instructions Pour L'assemblage Dans Un Casier

    Mise à Terre Sure—Une Mise à Terre Sure de l’équipement assemblé sur casier doit être effectuée. Faites particulièrement attention aux connexions électriques autres que les connexions directes sur les circuits annexes (par exemple, en utilisant une rallonge). © 2016 Edgewater Networks. All Rights Reserved.
  • Page 37: License And Warranty Information

    EdgeMarc Limited Hardware Warranty For a period of five (5) years from the date Edgewater Networks ships the Product to Purchaser (“Warranty Period”), Edgewater Networks warrants that such Hardware will be (i) free of defects in material and workmanship...
  • Page 38: Edgemarc Standard Limited Software Warranty

    OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE OR NON-INFRINGEMENT, AND ANY WARRANTIES ARISING OUT OF COURSE OF DEALING OR USAGE OF TRADE. EDGEWATER NETWORKS DOES NOT WARRANT THAT THE SOFTWARE IS ERROR FREE OR THAT THE SOFTWARE WIL BE WITHOUT INTERRUPTIONS, BUGS OR OTHER OPERATIONAL PROBLEMS.
  • Page 39: Limitation Of Liability

    License and Warranty Information Limitation of Liability IN NO EVENT SHALL EDGEWATER NETWORKS OR ITS THIRD-PARTY SUPPLIERS BE LIABLE FOR ANY LOSS OF USE, LOST DATA, FAILURE OF SECURITY MECHANISMS, INTERRUPTION OF BUSINESS, OR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY...