Configuration

5.1

Overview: Configuration

This chapter describes what you have to do and know to configure
the system after it is installed.
NOTICE
The explanation about the configuration in this chapter
gives you ONLY basic explanations. For more detailed
explanation and background information, see the installer
reference guide.
Why
If you do NOT configure the system correctly, it might NOT work as
expected. The configuration influences the following:
▪ The calculations of the software
▪ What you can see on and do with the user interface
How
You can configure the system via the user interface.
▪ First time – Quick wizard. When you turn ON the user interface
for the first time (via the indoor unit), a quick wizard starts to help
you configure the system.
▪ Afterwards. If necessary, you can make changes to the
configuration afterwards.
INFORMATION
When the installer settings are changed, the user interface
will request to confirm. When confirmed, the screen will
shortly turn OFF and "busy" will be displayed for several
seconds.
Accessing settings – Legend for tables
You can access the installer settings using two different methods.
However, NOT all settings are accessible via both methods. If so,
the corresponding table columns in this chapter are set to N/A (not
applicable).
Method
Accessing settings via the breadcrumb in the
menu structure.
Accessing settings via the code in the
overview settings.
See also:
"To access the installer settings" on page 13
"5.3 Menu structure: Overview installer settings" on page 19
EBLQ+EDLQ011~016CA3V3+W1
Daikin Altherma low temperature monobloc
4P537990-1 – 2018.05
X3M
X5M
Column in tables
#
Code
5.1.1

To connect the PC cable to the switch box

Prerequisite: The EKPCCAB kit is required.
1 Connect the cable with USB connection to your PC.
2 Connect the plug of the cable to X10A on A1P of the switch box
of the outdoor unit, or to X12A on A4P of the switch box of
control box EKCB07CAV3.
A
A1P
X10A
A
Outdoor unit switch box
B
Control box switch box
3 Pay special attention to the position of the plug!
2
NOTICE
Another cable is already connected to X10A. To connect
the PC cable to X10A, therefore temporarily disconnect
this other cable. Do NOT forget to reconnect it afterwards.
5.1.2

To access the most used commands

To access the installer settings
1 Set the user permission level to Installer.
2 Go to [A]:
> Installer settings.
To access the overview settings
1 Set the user permission level to Installer.
2 Go to [A.8]:
> Installer settings > Overview settings.
To set the user permission level to Installer
1 Set the user permission level to Adv. end user.
2 Go to [6.4]:
> Information > User permission level.
3 Press
for more than 4 seconds.
Result:
is displayed on the home pages.
5 Configuration
B
A4P
X12A
3
4
5
Installation manual