Kubota KX057-4 Operator's Manual page 73

Hide thumbs Also See for KX057-4:
Table of Contents

Advertisement

7. Press the switch 2 or 3 to preset the maximum flow
volume.
Set the bar to the highest level, and the flow volume
will be maximized.
Set the bar to the lowest level (no bar displayed), and
there will be no oil flow.
Then press the switch 4 to go to the next port, and
make the settings for all the other ports.
(1) Switch 2 (Higher flow volume)
(2) Switch 3 (Lower flow volume)
A Some attachments might not be activated even when
the bar level is still somewhat above the lowest
position. Or even when the bars of ports 1 and 2 (or of
ports 3 and 4) are at the same level, the same speed
might not be achieved. Those cases are not a machine
failure, however. Readjust the bar to the optimum level
according to your attachments.
A Suppose that the same attachment is mounted on
another machine. Even if the flow control setting is
made, the same speed cannot be achieved. Make an
optimum setting on each machine.
(A) "MAX. flow volume"
(B) "Output interrupted"
EXCAVATOR OPERATION
8. Go back to Step 3 to make settings for the next action
mode. When all the settings of all the action modes
have been made, press the switch 1 to return to the
normal screen.
(1) Switch 1
C AUX port MAX. Flow volume
MAX. flow volume
(Theoretical L/min)
MAX. pressure
MPa (kgf/cm ) [psi]
A When the AUX port is not used for a long period, dirt
particles can settle in the lower part of the AUX port
lines. When the plugs on the AUX port lines are
removed to connect attachments, drain approx. 100 cc
(3.4 oz) of oil before making connections.
AUX 1 port
AUX 2 port
75
37
(20)
(9.87)
17.2
17.2
(175)
(175)
[2500]
[2500]
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

U55-4

Table of Contents