Setting And Checking - SMC Networks HRS100 Series Operation Manual

Thermo chiller, communication function
Table of Contents

Advertisement

HRX-OM-S010
Chapter 2
Contact input/output communication
Contact input signal 2
11.
Press the [SEL] key once.
The set screen of contact input signal 2 is displayed on the digital display.
PV
SV
12.
Select contact input signal 2 from the table below with [▲] key or [▼] key, and confirm by
pressing "SEL".
Set values
1:When the setting of the serial protocol is "Simplified communication protocol 2",
"Remote signal input" cannot be set.
Contact input signal 2 type
13.
Press the [SEL] key once.
The set screen of contact input signal 2 type is displayed on the digital display.
PV
SV
14.
Select contact input signal 2 type from the table below with [▲] key or [▼] key, and confirm
by pressing "SEL".
Set values
1:Can be set when the setting of contact input signal 2 is "Run/Stop signal input" or "Remote
signal"

2.4 Setting and checking

2-8
Setting and checking
Table 2.4-7 List of set values
Explanation
Without signal input
Run/stop signal input
External switch signal input (N.O. type)
External switch signal input (N.C. type)
 1
Remote signal input
Setting and checking
Table 2.4-8 List of set values
Explanation
Setting/checking are not available if the
setting of contact input signal 2 is OFF.
Alternate signal
 1
Momentary signal
Initial value
(Default setting)
Initial value
(Default setting)
HRS100/150 Series