HomeMatic HmIP-FAL230-C10 Installation And Operaion Manual page 35

Floor heating actuator – 10 channels, 230 v
Table of Contents

Advertisement

Available languages

Available languages

Configuration via the Homematic IP Wall Thermostat
Duration
P007
of pump
protection
function
(only for
channel 1)
Switch off
P008
delay for
pump
(only for
channel 1)
Minimum
P045
floor
temperature
in connection
with a floor
temperature
sensor
68
128
0 minutes
129
1 minute (default)
...
...
137
9 minutes
138
10 minutes
128
0 minutes
129
1 minute
130
2 minutes (default)
...
...
147
19 minutes
148
20 minutes
10
5.0 °C
11
5.5 °C
...
...
38
19.0 °C (default)
...
...
59
29.5°C
60
30.0°C
Configuration via the Homematic IP Wall Thermostat
Humidity
P050
limit
Time interval
P051
for pump
protection
function
(only for
channel 1)
Cooling
P052
in cooling
mode
40
40 %: humidity limit
deactivated
...
...
80
80 %: humidity limit
deactivated
...
...
168
40 %: humidity limit
activated
...
...
188
60 %: humidity limit
activated (default)
...
...
208
80 %: humidity limit
activated
225
1 day
226
2 days
...
...
238
14 days (default)
...
...
251
27 days
252
28 days
0
Cooling in cooling
mode deactivated
1
Cooling in cooling
mode activated
(default)