To display available actions for an item, click the item in the ServeRAID Manager
tree and click Actions.

Configuring the Gigabit Ethernet controller

The Ethernet controller is integrated on the system board. It provides an interface
for connecting to a 10-Mbps, 100-Mbps, or 1-Gbps network and provides full duplex
(FDX) capability, which enables simultaneous transmission and reception of data on
the network. If the Ethernet port in the computer supports auto-negotiation, the
controller detects the data-transfer rate (10BASE-T, 100BASE-TX, or 1000BASE-T)
and duplex mode (full-duplex or half-duplex) of the network and automatically
operates at that rate and mode.
You do not have to set any jumpers or configure the controller. However, you must
install a device driver to enable the operating system to address the controller. For
device drivers and information about configuring the Gigabit Ethernet controller, go
to http://www.ibm.com/pc/support/

Using the SCSISelect Utility program (some models)

Use the SCSISelect Utility program to configure SCSI devices.

Starting the SCSISelect Utility program

To start the SCSISelect utility program, complete the following steps:
1. Turn on the computer.
2. When the prompt <<< Press <CTRL><A> for SCSISelect Utility! >>> prompt
3. Use the arrow keys to select a choice for which you want to change settings,
4. When the prompt Would you like to configure the SCSI controller or run
5. Use the arrow keys to select a choice from the menu.
6. Follow the instructions on the screen to change the settings of the selected

SCSISelect menu choices

The following choices are on the SCSISelect Utility menu:
v Configure/View SCSI Controller Settings
30
IntelliStation A Pro Type 6217: User's Guide
appears, press Ctrl+A. If you have set an administrator password, you are
prompted to type the password.
and press Enter.
the SCSI disk utility? appears, make your selection and press Enter.
items, and press Enter.
Select this choice to view or change SCSI controller settings. To reset the SCSI
controller to its default values, press F6 and follow the instructions on the screen.
You can view or change the following controller settings:
– SCSI Controller ID
Select this choice to view the SCSI controller ID, which is typically 7.
– SCSI Controller Termination
This choice is set to Enabled and cannot be changed.
– Boot Device Configuration
Select this choice to configure bootable-device parameters. You must know
the SCSI ID of the device that you want to configure.
– SCSI Device Configuration