Crestron Adagio™ AES
Operations Guide – DOC. 6456A
CEN-IDOC (Optional): The audio output of the CEN-IDOC must be
connected to source input port 5 on the AES when using the out-of-the-box
configuration. The CEN-IDOC and AES must be connected to the same
DHCP router.
AAS Devices (Optional): Source input ports 7 through 10 are reserved for
the different variations of the AAS. The AAS and AES must be connected
to the same DHCP router.
AAS-1: The audio output of the AAS-1 must be connected to source
input port 7.
AAS-2: Audio output A of the AAS-2 must be connected to source
input port 7 and audio output B must be connected to source input port
8.
AAS-4: Audio output A of the AAS-4 must be connected to source
input port 7. Audio output B must be connected to source input port 8.
Audio output C must be connected to source input port 9, and audio
output D must be connected to source input port 10.
Control Devices (Optional): Any combination of six APADs or
C2N-DBF12 devices can be connected to any of the six NET ports on the
rear of the AES. If an AAE is connected, six more APADs or C2N-DBF12
devices can be connected.
AAE (Optional): One AAE can be connected to the AES' loop-through
ports.
NOTE: The AAE must be set to its default Net ID value (31). For
information on setting the AAE's Net ID, refer to the latest version of the
AAE guide (Doc. 6460) which is available from the Crestron website.
The connections shown in the following diagram must be made for the AES to
properly control and switch connected devices when using the out-of-the-box
functionality.
CAUTION: Speakers must be rated to full available output.
CAUTION: Do not bridge speaker outputs.
CAUTION: All tuner cards should be securely installed in the AES.
CAUTION: Devices such as the AAS and the AAE must be fully grounded to the
AES. Additionally, any other source devices should be grounded to the AES as well.
NOTE: The AES can only be powered by the included power cord. Power cannot
be supplied from network devices that are connected to the mini-terminal block
connectors.
NOTE: The AESI (International version) requires a power cord that is harmonized
to the country's national and local electrical code. Each inner wire in the cord should
be at least 16 AWG or (1.5 mm
of the cord should be at least 60ºC. The cord length should be 1.5 meters to 2 meters.
Entertainment System
2
) and rated for at least 500V.The temperature rating
Entertainment System: Adagio AES • 17