Advertisement

SORRENTO
USER MANUAL
1
AH-SO-03
08/10/2017

Advertisement

Table of Contents
loading

Summary of Contents for Arjohuntleigh Sorrento

  • Page 1 SORRENTO USER MANUAL AH-SO-03 08/10/2017...
  • Page 2: Table Of Contents

    CONTENTS Introduction Clinical applications Installation Operation Cleaning Maintenance / Troubleshooting Accessories Warranty and Service Dimensions and Electrical Data Transportation and Storage Warnings, Cautions & Notes Warnings given in this manual identify possible hazards in procedures or conditions, which if not correctly followed could result in death, injury or other serious adverse reactions.
  • Page 3: Introduction

    1. Introduction The Sorrento is an electrically actuated nursing home and community care bed with multiple functions to aid the best nursing position for both patient and care giver. The following features, dependent upon the bed configuration, are available within the range: ...
  • Page 4: Clinical Applications

    2. Clinical Applications Area of Use General medicine, general and specialist surgery, care of the elderly, community care and nursing homes. Indications The use of the bed is to assist in patient positioning whilst reducing lifting and handling stresses for the care giver. Contra-indications The total safe working load of the bed is 200kg 3.
  • Page 5  Always use a mattress of the correct size and type. A range of suitable pressure reducing and pressure relieving mattress are available from ArjoHuntleigh.  When the bed is operated, make sure that obstacles such as bed side furniture do not restrict movement.
  • Page 6: Operation

    Safety Sides WARNING Safety Sides must only be used with an ArjoHuntleigh mattress of correct size which is approved for use with the bed. Maximum mattress thickness should be 170mm. The Clinically qualified person responsible should consider the age, size and condition of the patient before using Safety Sides.
  • Page 7 Bed extension (optional) To extend the bed: Apply the brakes, pull the latch lever (1) and pull out the foot-end of the mattress platform (3) Fold Down Foot Panel (optional) The Fold Down Foot Panel is to be strictly used as a bed stripper only, and should be returned back to its upright position thereafter Pull up to release To fold down;...
  • Page 8 Operation The bed height, backrest angle and leg elevation functions are all electrically operated using control handset. To operate a function, press and hold the appropriate pushbutton until the desired position is achieves. To stop at the required position release the button. The Auto-contour button operates both backrest and leg elevation simultaneously.
  • Page 9 Batteries (battery back-up model only) The emergency back-up battery automatically switches on if the bed is disconnected from the mains power supply. The batteries will enable emergency power operation for short periods of time. To ensure the batteries are kept fully charged the bed must be connected to the mains power supply at all times during normal use.
  • Page 10: Cleaning

    The following preventative maintenance procedures should be carried out at intervals of 12 months or as specified. All service or repair activities must only be performed by properly qualified and train persons who are approved by ArjoHuntleigh. Disposal of product and components should be compliant with local regulations. Warning Disconnect the bed from mains power supply before starting any maintenance activity.
  • Page 11 Individual Locking Castors Routine checks should be carried out every six months on the castor assemblies checking for looseness and general wear and tear. To do this, apply the brakes and lift the bed off the floor. Castors should be securely fixed within the castor tubes. If a problem is found, re-tighten the castor fixing bolts.
  • Page 12 HANDSET Checks Between each patient, ArjoHuntleigh strongly advises that the Handset is visually inspected for obvious damage before each use if practicable and that Preventative maintenance checks are conducted on the handset. When using a specific function staff should be aware of, and checking for, any of the symptoms listed in point 3 below.
  • Page 13  Feels soft offering no resistance  Feels different to the rest of the buttons  Travels further when depressed Immediately quarantine the bed and report the damage to maintenance staff or replace the Handset, otherwise contact an ArjoHuntleigh approved Technician. AH-SO-03 08/10/2017...
  • Page 14: Accessories

    SHP-SS38 8. Warranty & Service ArjoHuntleigh’s standard terms and conditions apply to all sales. A copy of the document is available upon request. The document contains the full details of warranty terms and conditions and does not limit the statutory rights of the consumer.
  • Page 15: Dimensions And Electrical Data

    9. Dimensions and Electrical Data Dimensions Overall Length 2145mm Extended 2325mm In-bed length 2035mm Extended 2215mm Overall width (incl. buffers) 1015mm 1145mm - King Single Height to mattress platform 100mm single castors 265 to 660mm 125mm single castors 295 to 695mm 150mm single castors 320 to 715mm Deck angles (Max.)
  • Page 16 10. Transportation and Storage Handle with care. Do not drop. Avoid shock or violent impact. The equipment should be stored in a clean dry and well ventilated area. The following limits apply during transport and for a storage period of up to 15 weeks.: Ambient temperature: -25°C +70°C...
  • Page 17 TEL: (+86-756)6326076 FAX: (+86-756)6326103 WEBSITE www.arjohuntleigh.com PERTH—ADELAIDE—MELBOURNE—SYDNEY—BRISBANE As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice. ArjoHuntleigh (ABN 75 007 200 900) A member of the Huntleigh Technology PLC Group of Companies AH-SO-03 08/10/2017...

Table of Contents