*IDN?
Return the AC source identification string
Return Parameter Chroma ATE 61600,123456,1.00,1.01,1.02
Chroma ATE
61600
123456
1.00, 1.01,1.02
*RCL<n>
Restore the values of the specific group which is previously stored in memory.
Parameter
*RST
This command resets the AC source to the initial states. It's better to wait
about 3 second to send the next command.
*SAV<n>
Save the values into the specific group in memory.
Parameter
*SRE
This command sets conditions of the Service Request Enabled Register. If
one or more of the enabled events of the Status Byte Register is set, the MSS
and RQS of Status Byte Register are set too.
*SRE?
This query returns the Service Request Enabled Register.
*STB?
This query returns the Status Byte Register.
Bit configuration of Status Byte Register
Bit Position
Condition
ESB = event status byte summary
QES = questionable status summary
RQS = request for service
MSS = master status summary
MAV = message available
*TST?
This command queries the self-test result of the AC source.
7.6.2

Instrument Command Dictionary

The commands are listed in alphabetical order. Commands followed by question marks (?)
take only the query forms. When commands take both the command and query forms, they
are noted in the query syntax descriptions.
: Company name
: Model name
: Serial number
: Firmware version of display, waveform and remote
1 - 3
1 - 3
7
6
5
- -
MSS
ESB MAV
RQS
Remote Operation
4
3
2
QUES
- -
1
0
- -
- -
7-7