Maintenance Procedures At 1,000 Hours Or 1 Year; Maintenance Procedures - Overview - Doosan DX140R Shop Manual

Hide thumbs Also See for DX140R:
Table of Contents

Advertisement

MAINTENANCE PROCEDURES
AT 1,000 HOURS OR 1 YEAR

Maintenance Procedures - Overview

General Information
All maintenance checks and inspections listed in previous
maintenance intervals must also be performed at this time, in
addition to those listed under this maintenance interval.
Maintenance Check
With the engine stopped, check the tensioner arm, pulley and
stops for cracks. If any cracks are found, the tensioner must be
replaced.
With the belt installed, verify that neither tensioner arm stops is
in contact with the spring casing stop. If either of the stops is
touching:
Verify the correct belt part number is installed.
If the correct belt is installed, replace the belt. Refer
to "Drive Belt, Cooling Fan" on page-115.
After replacing the belt, if the tensioner arm stops are still in
contact with the spring case stop, replace the tensioner.
Check the location of the drive belt on the belt tensioner pulley.
The belt should be centered on, or close to the middle of, the
pulley. Misaligned belts, either too far forward or backward, can
cause belt wear, belt roll-off failures, or increase uneven
tensioner bushing wear.
QSB4.5 Engine
Page 82
Figure 90
Figure 91
Figure 92
SP001671