REMOVAL

1.
Park on firm and level ground.
2.
Lower front attachment (bucket) to ground.
3.
Shut down engine.
4.
Set safety lever on "RELEASED" position.
5.
Turn starter switch to "I" (ON) position.
If
engine
must
maintenance, always use extreme caution. Always
have one person in the cab at all times. Never leave the
cab with engine running.
6.
Fully stroke work levers (joysticks) in all directions to
relieve any pressure from accumulators.
7.
Set safety lever on "LOCK" position.
8.
Turn key to "O" (OFF) position and remove from starter
switch.
9.
Hang a maintenance warning tag on controls.
10. Disconnect negative (-) battery cable leading to frame from
battery.
11. Remove cabin under cover by loosening bolts.
12. Tag and disconnect hoses from pedal valve (1, Figure 6).
Plug and cap hoses and ports to prevent contamination
from entering hydraulic system or component.