Test Run The Bath - Kohler K-1167 Installation Manual

Bath with airjets
Hide thumbs Also See for K-1167:
Table of Contents

Advertisement

Available languages

Available languages

Air Flow Mode
Activates Mode Selected
Rotate outer ring to access
desired mode.
Power On/Off

12. Test Run the Bath

NOTE: If the bath is not operating properly, consult the "Troubleshooting" section of this guide before
calling a qualified service representative.
NOTE: For additional information on operating the bath, see the "Operate the Keypad" section.
Preliminary Checks
Temporarily remove all access panels.
Ensure that the area around the blower is free of sawdust, insulation, dirt, or other small loose
debris.
Verify the union connection at the check valve is securely hand tightened.
Verify the piping from the blower to the butterfly valves is properly connected and supported.
Verify the piping from the check valve to the butterfly valves is properly connected and supported.
Ensure that the cable ties or other clips are supporting the air supply harness and electrical
harnesses at the bath.
Ensure any unused electrical connectors are supported above the floor.
Check all electrical connections. Verify the electrical power to the bath is turned on.
Ensure all PVC piping connections are tightened.
Confirm Blower Operation
Remove the protective drop cloth from the bath.
Fill the bath to a level at least 2" (51 mm) above the top of the highest airjet.
Press the POWER ON/OFF button on the user keypad.
Observe that the user keypad icons illuminate. The air flow mode icon and the chromatherapy cycle
icon (if provided) will illuminate green. The Zone 1, Zone 2, and Zone 3 icons are also illuminated
green since all three zones are activated.
Observe that the blower motor starts at a midrange speed.
1167629-2-A
Zone 1
Rotating Ring Key Pad
18
Zone 2
Zone 3
Surge Mode
Increase Flow or Surge
Indicator Bar
Decrease Flow or Surge
Purge Mode
Kohler Co.