Kohler K-1167 Installation Manual page 7

Bath with airjets
Hide thumbs Also See for K-1167:
Table of Contents

Advertisement

Available languages

Available languages

1/16"
(2 mm)
Tile
Approved Tile Backing
2. Prepare the Site - Concrete Construction
NOTICE: Do not support the bath by the rim.
NOTICE: Refer to the Roughing-in Guide packed with this product for proper minimum lbs/square foot
(kg/square meter) floor support loading.
NOTICE: Provide adequate ventilation and a minimum of 15 cubic feet (.4 cubic meters) in the installed
location for cooling the motor and to supply sufficient air for the blower. Do not install the blower motor
closer than 1" (25 mm) from the wall or other objects.
NOTE: This bath may be installed in an alcove installation.
Make sure the flooring offers adequate support for your bath, and verify that the subfloor is flat and
level.
Provide access panels as required to service the blower motor and control.
Construct brick or concrete supports.
Provide a 1/16" (2 mm) gap between the bath rim and the concrete or brick framing. Frame the
floor, or construct a frame for a raised installation, in accordance with the roughing-in information
packed with the bath.
Position the plumbing according to the roughing-in information packed. Cap the supplies, and
check for leaks.
Kohler Co.
Bath
Brick
Tile
Approved Tile Backing
Brick
7
Apron Side
1167629-2-A