8.6 Hydraulic rinse aid dispenser (CO MODELS)

Installation: Take the tube located in the back or your machine marked "Rinse Aid" and place inside
rinse container.
Tubes are transparent to provide you visible mean that chemicals are being dispensed.
Operation: This dispenser absorbs the rinse aid when it detects a loss in pressure during rinsing. That
is, when the filling solenoid valve closes, a vacuum is created that makes the rinse aid dispenser
absorb the fluid to which it is connected.
Adjustment: The dispenser should be adjusted when the machine is installed to ensure that the wash
is optimised from the start. The setting should be adjusted according to the type of rinse aid and the
water hardness.
WATER PRESSURE MUST BE MINIMUM 20 PSI AT THE PRESSURE GAUGE FOR THE RINSE
AID DISPENSER TO OPERATE PROPERLY.
20
Fig. 3. Installation of drainage at a height using drainage pump.
The drainage pump must only be installed by personnel authorised by the
manufacturer, and the manufacturer does not accept liability in the event of
incorrect installation.