3.4

Connection diagrams

For the four solar thermal systems (the four standard systems with possible options), the required
connections to the ISM modules are shown in Fig. 18 to 23.
Legend to Fig. 20 to 23 from page 120:
DWU1
Valve, return flow raising
DWUC
Priority/secondary valve (option C)
DWUF
Valve, temperature differential control
(option F)
FK
Solar collector
HK
Heating circuit
ISM 1
Module for standard solar thermal
systems
ISM 2
Module for extended solar thermal
systems
HP
Heating circuit pump
KW
Cold water connection
NTC
Temperature sensor connection
1...6
PA
Solar circuit pump for collector array 2
PB
DHW circulation pump for DHW
transfer system(option B)
PD
Secondary circuit pump for solar
thermal systems with external HE
(option D)
PE
Circulation pump for thermal
disinfection (option E)
R
Connection for pump or diverter valve
1...6
RE
Flow rate adjuster with indicator
RV
Non-return valve
SB
Gravity brake
SF
Cylinder temperature sensor (heating
appliance)
SP
Solar circuit pump for collector array 1
T
Collector temperature sensor array 1
1
T
Cylinder temperature sensor, bottom
2
(solar cylinder)
T
Cylinder temperature sensor at the
3
same height as the heating return
(solar cylinder)
T
Heating return temperature sensor
4
T
Cylinder temperature sensor, top
5
(solar cylinder)
6 720 645 355 (2010/09)
T
Standby cylinder temperature sensor,
6
bottom
TA
Collector temperature sensor for
collector array 2
TB
Cylinder temperature sensor for
cylinder 2 in the transfer system
TB
Temperature limiter
1...2
TC
Cylinder temperature sensor on
priority/secondary cylinder
(cylinder C)
TD
Temperature sensor on externalsolar
circuit indirect coil
TWM
Thermostatic DHW mixer
WW
DHW connection
T
Heat source temperature sensor for
F1
temperature differential control
(option F)
T
Heat sink temperature sensor for
F2
temperature differential control
(option F)
UL
Transfer pump to heat the standby
cylinder from the solar cylinder
(systems 3 and 4)
WS
Solar DHW cylinder
S
WS
Cylinder 2 (cylinder B) for DHW
B
transfer system
WS
Priority/secondary cylinder
C
(cylinder C)
WS
Standby cylinder (systems 3 and 4)
N
WT
Heat exchanger
WWKG
DHW comfort assembly
Z
DHW circulation connection
ZP
DHW circulation pump (if direct
connection to heating appliance is not
possible, connect to IPM)
en