Advertisement

Quick Links

Model
U1500E-NG11
Fuel Type
Minimum Supply Pressure
Manifold Pressure - High
3.5" W.C. (0.87 kPa)
Manifold Pressure - Low
1.6" W.C. (0.41 kPa)
Orifice Size -Altitude 0-4500 ft.
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
CSA P.4.1
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Direct Vent Pro®
Selkirk Direct-Temp™
American Metal Products®
Metal-Fab® Sure Seal
Security Secure-vent®
ICC Excel
Unit Dimensions
49-11/16"
(1263mm)
(1150mm)
U1500E-11 Gas Fireplace
U1500E-LP11
Natural Gas
Propane
5" W.C. (1.25 kPa)
11" W.C. (2.73 kPa)
10" W.C. (2.48 kPa)
6.4" W.C. (1.59 kPa)
#30 DMS
#48 DMS
29,000 BTU/h
33,500 BTU/h
(8.49 kW)
(9.82 kW)
43,000 BTU/h
42,000 BTU/h
(12.6 kW)
(12.3 kW)
5" Inner / 8" Outer
5" Inner / 8" Outer
67.46%
69.64%
54-5/16"
(1381mm)
49-11/16"
(1263mm)
8"
5"
45-1/4"
Unit Dimensions with Faceplate
23-15/16"
(608mm)
22-1/16"
(560mm)
54-5/16"
(1381mm)
49-11/16"
(1263mm)
53-1/2"
(1359mm)
49-11/16"
(1263mm)
45-1/4"
(1150mm)
U1500E-11 Gas Fireplace | 1

Advertisement

Table of Contents
loading

Summary of Contents for Regency U1500E-NG11

  • Page 1 U1500E-11 Gas Fireplace Model U1500E-NG11 U1500E-LP11 Fuel Type Natural Gas Propane Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa) Manifold Pressure - High 3.5” W.C. (0.87 kPa) 10” W.C. (2.48 kPa) Manifold Pressure - Low 1.6” W.C. (0.41 kPa) 6.4” W.C. (1.59 kPa) Orifice Size -Altitude 0-4500 ft. #30 DMS #48 DMS Minimum Input 29,000 BTU/h 33,500 BTU/h Altitude 0-4500 ft. (0-1372m) (8.49 kW) (9.82 kW) Maximum Input 43,000 BTU/h 42,000 BTU/h Altitude 0-4500 ft. (0-1372m) (12.6 kW) (12.3 kW)
  • Page 2: Framing Dimensions

    U1500E-11 Gas Fireplace Framing Dimensions Framing Description U1500E Dimensions Framing Height 47" (1194mm) Framing Width 55" (1397mm) Framing Depth 24-1/4" (615mm) Minimum Height to Combustibles 69-1/2" (1765mm) Corner Facing Wall Depth 65-3/4" (1670mm) Corner Facing Wall Width 93" (2362mm) Vent Centerline Height 41-3/8" (1051mm) Non-combustible facing height 23-7/8" (606mm) Gas Connection Opening Height 1-11/16" (43mm) Gas Connection Height 2-11/16" (67mm) Gas Connection Inset 1-1/8" (29mm) Gas Connection Opening Width 4-11/16" (119mm) * F raming depth measurement is noted with the nailing strips set as far forward on the firebox as possible. T he nailing strips can be adjusted back up to 1-1/2" (38mm) to allow for varying thicknesses in non-combustible material & wall finishes. See non combustible section in the instruction manual for details. Drywall or other facing Header...
  • Page 3 U1500E-11 Gas Fireplace Clearances The clearances listed below are minimum distances unless otherwise stated. A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest impor- tance that this fireplace and vent system be installed only in accordance with these instructions. Flue Pipe Clearances to Combustibles Clearance: Dimension...
  • Page 4: Mantel Leg Clearances

    U1500E-11 Gas Fireplace Mantel Clearances 6" 12" (305mm) (152mm) Due to the extreme heat this fireplace emits, the mantel clearances Drywall are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. 12" (305mm) 30" 6" (152mm) (762mm) Note: Ensure the paint that is used on the mantel and the facing is "high quality"...
  • Page 5: Non-Combustible Requirements

    U1500E-11 Gas Fireplace Non-Combustible Requirements * Installation of the ON/OFF Wall Switch/Battery Holder must be completed before installing non-combustible facing. All three pieces (top, 2 sides) are supplied to meet the non combustible requirements. Calcium silicate board is a high - grade Steel Stud Header material with cement, quartz, natural and on edge 56-1/2"...
  • Page 6: Framing And Finishing

    U1500E-11 Gas Fireplace Framing & Finishing 1. Frame in the enclosure for the unit with framing material. 5. If material such as brick, stone, etc extends past the faceplate depth 1-1/2", when finishing around the faceplate, the minimum opening IMPORTANT: The framed opening must be of non-combustible dimensions noted below must be adhered to ensuring for the removal material. of the faceplate and for the safe operation of this appliance. Note: When constructing the framed opening, please NOTE: Spacing of 1"around the completed surround must be adhered to. ensure there is access to install the gas lines when the unit is installed.
  • Page 7 Horizon Fireplace is no exception to this rule. Therefore, the units are specified with non-combustible required materials to specific dimensions above and around the units. This is due to these areas reaching higher temperature levels than required/acceptable for a combustible material. To obtain the best, most durable finish around your fireplace, this calls for a high level of care and attention to the preparation and finish around this appliance, using only the highest quality materials, able to withstand the temperatures produced. By following the installation instructions in the manual exactly, you will increase your chances of a damage free finish. While every precaution is taken in providing the recommendations on preparation and finish, given the variations in paint quality, with temperature limits and workmanship in application, Regency is unable to guarantee the life of the joint compounds, paint or any other finish materials or workmanship applied to or used in any application surrounding the fireplace. This includes framing as well as finishing. Over time natural convection from any fireplace can cause discoloration in the area directly above the appliance. Lower quality paints, under-prepared finishes, poor applications, and any framing discrepancies or in the installation can cause this discoloration process to be expedited. Discoloration is not the responsibility of Regency Fireplace Products. This is out of the control of Regency Fireplace Products Ltd., therefore not covered under any part of the warranty policy. While discoloration is not the responsibility of Regency Fireplace Products, we believe careful attention to the recommendations provided here will result in an aesthetically pleasing result free of issues outlined above. U1500E-11 Gas Fireplace | 7...
  • Page 8: Optional Framing Kit

    U1500E U1500E-11 Gas Fireplace Optional Framing Kit OPTIONAL FRAMING KIT 1. Construct the timber framing, ensure inside dimensions are 48-5/8" H x 55" W as shown below. 55" 48-5/8"" (676-036)A Flat side out 5. Secure horizontal steel header stud (606-067) with 2 screws per side as 2.
  • Page 9: Venting Introduction

    Vent restrictor factory set at Set 0. Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used.
  • Page 10: Venting Arrangement For Vertical Terminations

    U1500E-11 Gas Fireplace Venting Arrangement for Vertical Terminations Vertical Venting with One(1) 90 Elbows (1 - 90 2 - 45 ) with straight Vertical and or a maximum offset using 2 - 90 elbows The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90 elbow, with Rigid Pipe Venting Systems. Two 45 elbows equal to one 90 elbow.
  • Page 11 U1500E-11 Gas Fireplace Vertical Venting with Three (3) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 V + V1 With these options, 0' Min. 2' Max. 2' Min. max. total pipe length 1' Min. 2' Max 3' Min. is 30 feet with min. of 2' Min. 3' Max 4' Min. 10 feet total vertical and max. 8 feet total 3' Min.