Download Print this page

Ricoh Pro C9100 Series Technical Bulletin page 36

Hide thumbs Also See for Pro C9100 Series:

Advertisement

Model: Vacuum Feed LCIT RT5100
4. Measure the distance (span) between the two side plates (Fig. 2).
Important: The scale ends should touch the bent portion of the side plates.
5. Take the same measurement with the tray in the middle and lower positions (Fig. 3).
6. Measure the clearance between the bent portion of the side plate and the bearing
flange.
Important: To do this, shift the bottom plate toward the rear side (Fig. 4).
T
B
echnical
Fig. 2
Fig. 3
Fig. 4
ulletin
Date: 3-Aug-16
PAGE: 2/8
No.: RD777009