Specifications/Dimensions - STA-RITE JWPD-075 Owner's Manual

Table of Contents

Advertisement

Figure 1: Dimensions In Inches (mm)
TABLE I - RECOMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 HZ MOTORS
Model
Motor
No.
H.P.
JWPD-075
3/4
JWPE-100
1
JWPF-150
1-1/2
Values given in tables below are for PUMP MOTOR ONLY. If additional
accessories are installed on pump motor circuit (heater, blower, etc.), in-
clude their amperage draw when figuring wire and circuit breaker sizes.
Voltage/
Full Load
Hz/Phase
Amps
115/60/1
9.2
115/230/60/1
12.0/6.0
115/230/60/1
16.0/8.0
Branch
Circuit Breaker
Dist. in Ft. (M)-Service Motor
Rating (amps)
0-100' (0-30)
15
14
15
14/14
20/15
12/14
4
Wire Gauge Size
101-200' (31-60) 201-300' (61-90)
12
10
10/14
8/14
8/14
6/12
Temp.
Rating-°C
75
75
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jwpe-100Jwpf-150

Table of Contents