To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘JT’ Series Tub Pump: • Is designed to circulate hot water in jetted tubs. • Is an excellent performer; durable, reliable.
• Check all clamps, bolts, lids, and system accessories before testing. • Release all air in system before testing. • Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing. • Water pressure for test must be less than 25 PSI (172 kPa).
INSTALLATION Installation and wiring of pump should only be done by qualified, licensed personnel. Pump mount must: Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Be installed with pump suction inlet higher than tub suction fitting. (This al- lows pump to drain completely when tub is drained.) Have pump suction below tub water level when pump is running.
ELECTRICAL Ground motor before connecting to electrical power supply! Failure to ground pump motor can cause serious or fatal electrical shock hazard! Do not ground to a gas supply line! To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
Page 6
Dist in Ft. (M) - Service to Motor Model Motor 0-100 101-200 201-300 Temp. H.P. (0-30) (31-60) (61-90) Rating-°C JTACLC-A 14 (2.0) 12 (3.0) 10 (5.5) Wire Size JTADLC-2A 14 (2.0) 10 (5.5) 8 (8.4) JTAELC-2A 14 (2.0) 10 (5.5) 8 (8.4)
OPERATION Priming Pump: NEVER run pump dry! Running pump dry may damage seals, causing leakage and flooding! Fill tub to 2 inches (51mm) above top of jets before starting system. Do not block pump suction! To do so with body may cause severe or fatal injury.
PUMP SERVICE Pump should only be serviced by qualified personnel. To avoid dangerous or fatal electrical shock hazard, disconnect power to motor before working on pump or motor! No lubrication or regular maintenance are needed. If shaft seal is damaged, repair as follows: Hazardous voltage.
Page 9
Installing New Seal: 1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet rubber cup gasket of ceramic seat with small amount of liquid detergent; press into cavity firmly and squarely with finger pressure (Figure 5). 2.
TROUBLESHOOTING GUIDE Read and understand safety and operating instructions in this manual before doing any work on pump! A. PUMP DOES NOT OPERATE 1. Check GFCI for proper operation according to GFCI manufacturer’s in- structions. 2. Check for plugged impeller. Follow disassembly/assembly instructions under “Pump Service”, Page 8.
REPAIR PARTS LIST DURA-JET TUB PUMP Model No. JTACLC-A JTADLC-2A JTAELC-2A Description Qty. 1/2 HP 3/4 HP 1 HP Motor - 115/60Hz/1PH(-A) AS900CLL AS920DLL AS920ELL Slinger C69-2 C69-2 C69-2 Impeller Shim (.010)* C43-21D C43-21D C43-21D Impeller Shim (.0299)* C43-22D C43-22D...
The foregoing warranties relate to the original consumer pur- chaser (“Purchaser”) only. Sta-Rite shall have the option to re- HRPB, DEPB, System 3, and PL – Tanks ..10 years pair or replace the defective product, at its sole discre- Internal filter components and valves .
Need help?
Do you have a question about the JTACLC-A and is the answer not in the manual?