To avoid unneeded service calls, prevent possible injuries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-Rite ‘JT’ Series Tub Pump: • Is designed to circulate hot water in jetted tubs. • Is an excellent performer; durable, reliable.
• Check all clamps, bolts, lids, and system accessories before testing. • Release all air in system before testing. • Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing. • Water pressure for test must be less than 25 PSI (172 kPa).
INSTALLATION Installation and wiring of pump should only be done by qualified, licensed personnel. Pump mount must: Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.) Be installed with pump suction inlet higher than tub suction fitting. (This al- lows pump to drain completely when tub is drained.) Have pump suction below tub water level when pump is running.
ELECTRICAL Ground motor before connecting to electrical power supply. Failure to ground pump motor can cause serious or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
Page 6
Voltage: Voltage at motor must be not more than 10% above or below motor name- plate rated voltage or motor may overheat, causing overload tripping and re- duced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult power company.
OPERATION Priming Pump: NEVER run pump dry! Running pump dry may damage seals, causing leakage and flooding! Fill tub to 2 inches (51mm) above top of jets before starting system. Do not block pump suction! To do so with body may cause severe or fatal injury.
PUMP SERVICE Pump should only be serviced by qualified personnel. To avoid dangerous or fatal electrical shock hazard, disconnect power to motor before working on pump or motor! No lubrication or regular maintenance are needed. If shaft seal is damaged, repair as follows: Removing Old Seal: 1.
TROUBLESHOOTING GUIDE C. EXCESSIVE AIR IN SYSTEM – PUMP LOSES Read and understand safety and operating instruc- tions in this manual before doing any work on PRIME pump! 1. Make sure water level in spa is at least 2" (51 mm) above top of jets with system not operating.
REPAIR PARTS LIST DURA-JET TUB PUMP 1162 0695 Model No. JTADL-AA JTAEL-AA JTADL-2A JTAEL-2A JTADL-220AA JTAEL-220AA JTACL-AA JTAD-230A JTAE-230A JTAFL-2A Description Qty. 1/2 HP 3/4 HP 1 HP 1-1/2 HP Motor - 115/60Hz/1Ph(-AA) AS900CLL-A AS900DLL-A AS900ELL-A — Motor - 115/60Hz/1Ph(-2A) —...
The foregoing warranties relate to the original consumer pur- chaser (“Purchaser”) only. Sta-Rite shall have the option to re- HRPB, DEPB, System 3, and PL – Tanks ..10 years pair or replace the defective product, at its sole discre- Internal filter components and valves .
Need help?
Do you have a question about the JTACL1/2 HP and is the answer not in the manual?