International Breathing-Air Standards
Europe
BS
EN12021:2014
Odour
The gas shall be free
from
odour or taste.
Oxygen
(21 ± 1)%
Carbon
≤ 500 PPM
Dioxide
Carbon
≤ 5 PPM
Monoxide
Oil
≤ 0.5 mg/m
Water
Where the apparatus
Airline
is used and stored at a
<40Bar
known temperature
the
dewpoint shall be at
least 5°C below likely
lowest temperature.
Where the conditions
of usage and storage
of any compressed air
supply is not known
the
dewpoint shall not
exceed -11°C.
Water
40 to 200 bar ≤50
High
mg/m
Pressure
>200 bar ≤35 mg/m
HP Charging Comp
≤25 mg/m
Note – Also ensure that the test point volume and pressure is sufficient for the RPD being used. For
AS-NZS 1715 the minimum requirement is 170 l/min continuous flow for each person, measured at
the respirator.
Above is an extract only for full details refer to the individual standards.
US
EN12021
&
CGA
Grade D
None (No pronounced
unsatisfactory
odour)
19.5% - 23.5%
≤ 1000 PPM
≤ 10 PPM
3
≤ 5 mg/m
Dewpoint ≤50°F (67
PPM v/v), for SCBA
use in extreme cold a
pressure
dew point not to
exceed -65°F (24 ppm
v/v) or the dewpoint
must be 10°F lower
than
temperature
the respirator is worn.
pressure
3
3
3
Australia and New
Zealand
G-7.1-2011
AS-NZS 1715: 2009*
No objectionable or
nauseous odour
19.5% - 22%
≤ 800 PPM
≤ 10 PPM
3
≤ 1 mg/m
the
coldest
where
Contain
than 100 mg/m
cylinders initially filled
to pressure of at least
120 bar.
24
3
not
more
3