Page 1
The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel. If you have any queries about the installation or the certification of the unit – please contact Raytec for immediate assistance and advice.
3. Special Conditions of Use – Equipment must only be installed in a position that satisfies a low risk of mechanical danger from impact. (4 J) If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec. 5. Externally the SPARTAN unit housing is constructed from marine grade aluminium, and toughened glass, stainless steel brackets/fasteners and silicone gaskets, internally there are many non metallic components.
2. Installation Mounting SPARTAN Unit 1. To meet the requirements of certification a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. The product is supplied with 2xM8 grub screws for mounting (see point 4 and 5) The line diagrams below are for guidance only UK /Europe Tel: +44 (0) 1670 520055 www.raytecled.com...
Page 4
The SPARTAN Street is delivered in two parts; the main body of the luminaire, and the pole mount arm. These two parts must be assembled prior to installation. Luminaire and Pole Mount Bracket Assembly • Feed the supply cable through the pole mount arm before securing it to the luminaires main body.
Mechanical installation • Mount unit on an appropriately sized pole. • Secure unit onto pole using supplied grub screws. Ensure pole is fully engaged and tighten grub screws to torque 17nm (5mm hex). Electrical connection, connect mains supply cable to mains supply at base of column. If the unit is opened for any reason, disconnect mains If carrying out Insulation Resistance tests the normal method of insulation testing is to connect Live and Neutral together and test between this point and Earth to prevent the...
4. Technical Specification 110-254V AC Input Voltage 0.26A Input Current (230Vac, full load) Consumption >0.97 Power Factor (230Vac, full load) 50/60Hz Mains Frequency 23A, ∆t < 136µs Inrush Current (I @50%) peak < 1 0 % Total Harmonic Distortion (230Vac, fullload) IP66 IP Rating Weight (std)
Page 7
& UK Directive SI 2016 No. 1107 (as amended) Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 2014/34/EU of 20th April 2016 and UK Directive SI 2016 No. 1107...
Page 8
Raytec Global (excluding Americas) Raytec Americas Tel: + 4 4 (0) 1670 520055 Tel: + 1 613 270 9990 sales@raytecled.com ussales@raytecled.com Raytec Ltd. Raytec Systems Inc. Unit 15 Wansbeck Business Park, Rotary Parkway 800-300 Terry Fox Drive, Ottawa, Ontario Ashington, Northumberland, NE63 8QW, United Kingdom 2K 0E3, Canada raytecled.com...