Key/Display
Operation
Switching the appliance on and off
It is possible to switch the appliance on or off (stand-by) by pressing the specific button. The control
system of the appliance is equipped with a memory, so settings will not be lost if the appliance is
switched off or in the power supply is cut. This key is used to activate or deactivate the appliance for
short periods of time.
the main switch or the plug from the socket.
Well-being button (economic automatic mode)
By choosing this mode on the appliance, it sets the best level of comfort in the room. The conditioner
selects the mode automatically (cooling or heating) according to the temperature set and ventilation
speed according to the temperature of the room.
Cooling only mode
In this mode, the appliance dehumidifies and cools the room.
It is possible to set the desired temperature between 16 and 31°C and, if this temperature is lower than
the room temperature, the compressor starts up after three minutes (maximum) and the appliance
starts dispensing cool air, maintaining ventilation active even if the setpoint has been reached.
Dehumidification only mode
In this mode, the appliance dehumidifies the room. Selecting this mode is useful during mid-seasons,
i.e. on days (e.g. rainy ones) when the temperature is pleasant, but excess humidity causes discomfort.
This mode ignores both room temperature and ventilation speed settings.The latter is always set to a
minimum. It is normal for the appliance to work intermittently.
Ventilation only mode
By selecting this function, the compressor is never activated and the appliance does not affect either
room temperature or humidity. it is possible to choose the speed of the fan
Heating only mode
In this mode, the appliance heats the room.
During this phase, the conditioner does not dispense warm air, even if its internal components are on,
except for the room fan.
It is possible to set the desired temperature between 16 and 31°C and, if such temperature is higher
than the room temperature, the compressor starts up after three minutes (maximum) and the appliance
starts dispensing warm air.
Nocturnal well-being button
While the appliance is on in the selected cooling or heating mode, it is possible to choose different
functions by pressing the button in order to maximise noise reduction, energy saving and nocturnal
well-being regulation.
In this mode, ventilation is set on minimum speed.
This mode should be activated right before going to sleep.
• In cooling mode, the set temperature is increased by 1°C after one hour and by another degree after
two. After the second hour, the temperature is no longer changed and, after six hours, the appliance
is put in stand-by.
• In heating mode, the set temperature is lowered by 1°C after one hour and by another degree after
two. After the second hour, the temperature is no longer changed and, after six hours, the appliance
is put in stand-by.
This function is not available for dehumidification only, ventilation only and economic automatic
modes and can be excluded any time (ideally once awake) by pressing the button again.
If the Timer has also been set, the appliance will turn off at the set time.
6
Soloclim Vertical - Utilisation
In case of long periods of inactivity, the appliance must be deactivated by disconnecting either
Set on heating only mode, the appliance periodically defrosts the evaporator coil, if necessary.