10.1 Lubrication

See sect. 10.3, Table 3, for lubrication chart.
All ball bearings are permanently lubricated and
sealed. They require no further attention.
Use a light machine oil to lubricate moving parts as
needed.
Periodically apply light coat of machine oil to
exposed metal surfaces, such as vise bed, to
prohibit rust.
10.1.1 Gear box
Drain and refill gear box according to Table 3
recommendations.
Use sight glass (A, Figure 11-2) to check oil level.
To change gear box oil:
1.
Connect machine to power and raise bow to a
convenient position. Press E-stop.
2.
Unscrew and remove drain plug beneath gear
box, and allow lubricant to drain completely.
Follow local regulations for proper disposal of
used oil.
Figure 11-2: gear box drain and fill
3.
Reinstall drain plug.
4.
Remove fill plug (B) and insert approximately 2L
(1/2 gal.) of
Mobil
equivalent, until oil fills the sight glass.
5.
Reinstall fill plug.
10.1.2 Servicing hydraulic oil
1.
Disconnect machine from power source.
2.
Remove hydraulic tank access panel.
3.
Check oil level (E, Figure 11-3). If level is below
yellow (upper) line, the reservoir should be
filled.
4.
Disconnect electrical power.
5.
Slide out hydraulic tank assembly to access the
fill cap.
6.
Remove fill cap (not shown).
7.
Add oil up to yellow (upper) line. Install fill cap.
®
SHC Gear Oil 460
, or
8.
If a significant amount of oil must be added,
check for oil leaks in pump components, lines,
and hydraulic cylinder. Correct source of
leakage before operating saw.
9.
Connect electrical power. Raise and lower bow
to confirm that saw is operating correctly.
Figure 11-3: hydraulic oil servicing
10.1.3 Coolant
JET offers a bio-degradable, concentrated flood
coolant (not provided) formulated for band saws,
lathes,
and
milling
water/coolant mix ratio. See JET website for more
information and to order.
414124 JET Bio-Degradable Flood Coolant, 1/2 Gal.
414126 JET Bio-Degradable Flood Coolant, 1 Gal.
414127 JET Bio-Degradable Flood Coolant, 5 Gal.
Filling and Draining
Pour coolant mixture into chip tray so that it drains
through strainer into basin. The sight glass is
located on front of base.
Numerous cutting fluids on the market are
formulated for special applications. Consult your
local distributor for details if you have a long range
production task or are required to cut more exotic
materials. Refer to the cutting fluid provider's
instructions for mixing recommendations and fluid
life span.
To drain coolant, use drain plug located on front of
machine stand. Follow local regulations when
disposing of used machine fluids. Apply thread
sealing tape to the drain plug before re-installing.
Keep the overflow hole on right side of base, clean
and unobstructed.
Different brands of coolant may not mix properly. If
changing to new brand, first flush coolant line and
sump with an industrial degreaser or cleaner that
does not contain silicone or petroleum based
ingredients.
13