Dimensions and Mounting
Polypropylene (1050P), Conductive Polypropylene (1050C) and
PVDF (1050F)
A
13.2 in. (335 mm)
B
15.7 in. (399 mm)
C
17.8 in. (452 mm)
D
12.0 in. (305 mm)
E
2.5 in. (63.5 mm)
F
8.0 in. (203 mm)
G
Center Flange: 16.0 in. (406 mm)
End Flange: 15.2 in. (386 mm)
H
6.2 in. (158 mm)
J
3.9 in. (99 mm)
K
10.2 in. (258 mm)
20
ti13845b
ti13846b
NOTE: Listed dimensions are accurate for both center and
end flange models, except where noted.
L
1/2 npt(f) air inlet
M
1 in. ANSI/DIN flange
N
1 in. ANSI/DIN flange
P
3/4 npt(f) air exhaust port
R
Polypropylene (1050P):
10.42 in. (265 mm)
Conductive Polypropylene (1050C):
10.55 in. (268 mm)
PVDF (1050F): 10.37 in. (263.4 mm)