Warnings Warnings Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings.
Page 4
Warnings WARNING WARNING WARNING EQUIPMENT EQUIPMENT EQUIPMENT MISUSE MISUSE MISUSE HAZARD HAZARD HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component.
Page 5
Warnings WARNING WARNING WARNING TOXIC TOXIC TOXIC FLUID FLUID OR FLUID OR FUMES FUMES HAZARD FUMES HAZARD HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDSs to know the specific hazards of the fluids you are using. •...
Please Please call call call your your distributor. your distributor. distributor. references on these two pages for further ordering information, as needed. 3. Please call Graco Customer Service to order. Related Manuals Manuals Related Related Manuals Manual Manual Manual Number...
Configuration Number Matrix Configuration Configuration Configuration Number Number Matrix Number Matrix Matrix Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump. 15120P 15120P 15120P- - - PP01AP1PPPTFKPT PP01AP1PPPTFKPT PP01AP1PPPTFKPT Sample Configuration...
3. Reduce liquid velocity: Slow the cyclic rate of selecting and installing system components. Contact the pump. your Graco distributor for assistance in planning a Pumped liquid viscosity is also very important but system to suit your needs. Always use Genuine normally is controlled by factors that are process Graco Parts and accessories.
Page 9
Installation Figure 1 Typical Installation Accessories/Components Not Not Supplied Supplied System Components Components Accessories/Components Accessories/Components Supplied System System Components Air supply line Air inlet port (not visible) Bleed-type master air valve (may be required for Air outlet port and muffler your pump installation) Air filter/regulator assembly Fluid inlet port...
Installation Ground The The System System Air Lines Lines Lines Ground Ground System 1. Install an air filter/regulator assembly (C). The regulator controls the fluid pressure. The fluid stall pressure will be the same as the setting of the air regulator. The filter removes harmful dirt The equipment must be grounded to reduce the and moisture from the compressed air supply.
Installation Air Exhaust Exhaust Exhaust Ventilation Ventilation Ventilation To provide provide a a a remote remote exhaust: exhaust: provide remote exhaust: 1. Remove the muffler (U) from the pump air exhaust port (K). If pumping toxic fluids, you must vent the exhaust 2.
Installation Fluid Fluid Fluid Supply Supply Supply Line Line Line Fluid Fluid Fluid Outlet Outlet Outlet Line Line Line 1. Connect a grounded, flexible fluid hose (E) to the 1. Connect a grounded, flexible fluid hose (H) to the 1.5 in (38 mm) ANSI/DIN pump fluid inlet flange 1.5 in (38 mm) ANSI/DIN pump fluid outlet flange (L).
The fluid inlet and outlet ports are 1.5 in (38 mm) raised face, standard 150 lb (68 kg) class pipe flanges. Graco standard pipe flange kits are available in polypropylene (239006) and PVDF (239010). These kits include: • the pipe flange •...
Operation Operation Operation Operation Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure 3. Place the suction tube (if used) in fluid to be pumped. Follow the Pressure Relief Procedure NOTE: If fluid inlet pressure to the pump is more NOTE: NOTE: whenever you see this symbol.
Maintenance Maintenance Maintenance Maintenance Maintenance Schedule Schedule Flushing and and Storage Storage Maintenance Maintenance Schedule Flushing Flushing Storage Establish a preventive maintenance schedule based on the pump’s service history. Scheduled maintenance is especially important to prevent spills or leakage due to diaphragm failure. Lubrication Lubrication Lubrication...
Torque Instructions Torque Torque Torque Instructions Instructions Instructions If fluid cover or manifold fasteners have been Inlet and and Outlet Outlet Manifold Manifold Screws Screws Inlet Inlet Outlet Manifold Screws loosened, it is important to torque them using the following procedure to improve sealing. NOTE: NOTE: NOTE: Fluid cover and manifold fasteners have a...
Technical Data Technical Technical Technical Data Data Data Husky 15120 15120 Diaphragm Diaphragm Pump Pump Husky Husky 15120 Diaphragm Pump Metric Metric Metric Maximum fluid working pressure 125 psi 0.86 MPa, 8.6 bar Air pressure operating range 20 to 125 psi 0.14 to 0.86 MPa, 1.4 to 8.6 bar...
Page 23
Technical Data Maximum Maximum pump Maximum pump pump speed speed speed 1–piece bolt-through diaphragms 192 cycles per minute 2–piece bolt-through diaphragms 183 cycles per minute Overmolded diaphragms 195 cycles per minute Weight Weight Weight Polypropylene 57 lb 25.9 kg PVDF 74 lb 33.6 kg Wetted...
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts.