Notes On Cleaning Metering Pumps With Hygienic Pump Head; Properties Of Wetted Parts; Cleaning By Flushing - ProMinent 10022 Supplementary Operating Instructions

Sigmas with hygienic pump head
Table of Contents

Advertisement

Notes on cleaning metering pumps with hygienic pump head

3
Notes on cleaning metering pumps with hygienic pump head

3.1 Properties of wetted parts

Materials of wetted parts
Dosing head
Valve seats / valve housing / connector section
1.4435
Wetted surfaces

3.2 Cleaning by flushing

General
20
The following wetted materials are used in ProMinent metering pumps with
hygienic pump head:
1
2
3
4
5
6
7
Fig. 13: Cross-section through the Sigma Hygiene liquid end
1
O-ring
2
Connector section
3
Valve housing
4
Ball
5
Valve seat
6
Dosing head
7
Diaphragm
1.4435
The materials conform to Regulation (EC) no. 1935/2004.
* O-rings DIN 11864 R; the release of individual particles when exposed to
high thermal load is possible - then shorten the maintenance intervals.
Make sure that the wetted surfaces are not scratched or damaged.
The metallic, wetted surfaces are electropolished with Ra max. 0.8 μm.
Do not scratch or damage the wetted side of the diaphragm.
Do not exceed the chloride content of the batching water (see
cleaning agents and parameters' on page 22 and Ä 'Selected disinfec‐
tants and parameters' on page 22 ), because the steel parts can then
become unhygienic due to corrosion.
ProMinent recommends including the metering pump with hygienic pump
head in an HACCP and/or in-house hygiene scheme.
O-rings *
Balls
Diaphragm
EPDM
Al
O
PTFE
2
3
Ä 'Selected
B1285_3

Advertisement