Download Print this page

Immergas EOLO Star Instruction Booklet And Warning page 139

Hide thumbs Also See for EOLO Star:

Advertisement

Eolo Star variable heat output.
OUTPUT
OUTPUT
HEAT
HEAT
(kcal/h)
(kW)
20000
23,3
19000
22,1
18000
20,9
H
17700
20,6
E
A
16000
18,6
T
15000
17,4
I
N
14000
16,3
G
13000
15,1
12000
14,0
11000
12,8
10000
11,6
9000
10,5
8000
9,3
6000
7,0
Domestic
N.B.: Pressure values specified in the table indicate the difference of
pressure values between the gas valve outlet and the combustion
chamber. Adjustments are therefore carried out with the differential
pressure gauge ( "U" or digital type) with the sensors inserted in the
test pressure outlet of the modulating adjustable gas valve and on
Eolo Star technical specifications.
Nominal heating capacity
Min. heating capacity
Nominal heat output (useful)
Min. heat output (useful)
Useful heating efficiency at nominal output
Useful heating efficiency at 30% nom. output
Heat loss at shell with burner On/Off
Heat loss at flue with burner On/Off
Diam. nozzles
Feed pressure
Max. working pressure heating circuit
Max. working temp. heating circuit
Adjustable temp. heating
Total volume expansion tank
Expansion tank precharge
Water content of generator
Available head with flowrate 1000 l/h
Useful heat output hot water production
Domestic hot water adjustable temp.
Flow limiter
Min. pressure (dynamic) domestic circuit
Max. working pressure domestic circuit
Min. drawing domestic hot water
Drawing capacity in continuous service (∆T 30 deg. C)
Specific capacity (∆T 30 deg. C)
Min. pressure for flow limiter capacity
Weight of boiler full
Weight of boiler empty
Electrical connection
Nominal absorption
Installed electrical power
Power absorbed by circulating pump
Power absorbed by fan
Appliance electrical system protection
Fumes flowrate in mass at nominal output
Fumes flowrate in mass at min. output
CO
at Nom./Min. Q.
2
CO at 0% O
at Nom./Min. Q.
2
NO
at 0% O
at Nom./Min. Q.
x
2
Fumes temp. at nom. output
Fumes. temp. at min. output.
Flue temperature values refer to air inlet temperatures of 15°C.
NATURAL GAS (G20)
GAS
NOZZLES
FLOWRATE
PRESSURE
BURNER
BURNER
(m3/h)
(mbar)
(mm H20)
2,72
10,7
109
2,60
9,8
100
2,47
8,8
90
2,43
8,5
87
2,21
7,0
72
2,08
6,3
64
1,96
5,5
56
1,83
4,8
49
1,70
4,2
43
1,58
3,6
37
1,45
3,0
31
1,32
2,5
26
1,19
2,3
23
0,88
1,1
11
BUTANE (G30)
GAS
NOZZLES
FLOWRATE
PRESSURE
BURNER
BURNER
(kg/h)
(mbar)
(mm H20)
2,03
27,7
283
1,94
25,3
258
1,84
22,8
232
1,81
22,1
225
1,65
18,2
186
1,55
16,2
165
1,46
14,3
146
1,36
12,5
128
1,27
10,8
111
1,17
9,3
95
1,08
7,9
80
0,98
6,5
67
0,89
5,6
57
0,65
3,0
31
the sealed chamber positive pressure test outlet. Power data
specified in the table refer to a 0,5 metre intake/exhaust pipe. Gas
flow rates refer to heat power below temperature of 15°C and at a
pressure of 1013 mbar. Burner pressure values refer to use of gas at
15°C.
kW (kcal/h)
25,7 (22124)
kW (kcal/h)
11,2 (9674)
kW (kcal/h)
23,3 (20000)
kW (kcal/h)
9,3 (8000)
%
%
%
%
G20
mm
1,30
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
23,03 (2,35)
2
kW (kcal/h)
23,3 (20000)
°C
l/min
bar
bar
l/min
l/min
l/min
bar
kg
kg
V/Hz
A
W
W
W
-
G20
kg/h
58
kg/h
61
%
6,3/2,5
ppm
58/70
ppm
68/50
°C
122
°C
100
PROPANE (G31)
GAS
NOZZLES
FLOWRATE
PRESSURE
BURNER
BURNER
(kg/h)
(mbar)
(mm H20)
2,00
35,7
364
1,91
32,6
333
1,81
29,4
300
1,78
28,4
290
1,62
23,5
240
1,53
20,9
213
1,44
18,4
188
1,34
16,1
164
1,25
14,0
143
1,16
12,0
122
1,06
10,1
103
0,97
8,4
86
0,87
7,2
73
1,06
3,6
37
90,4
88,5
2,1/0,53
7,5/0,02
G30
G31
0,77
0,77
29 (296)
37 (377)
3
90
35 - 80
6
1,0
3,5
35 - 55
8
0,26
10
2,5
11,1
10,7
1
38
34
230/50
0,8
140
63
46
IPX4D
G30
G31
56
56
61
61
7,6/2,9
7,5/2,9
115/85
66/79
226/134
200/103
122
123
101
100
ES
PT
GR
PL
TR
CZ
HR
SL
HU
RU
RO
GB
137

Advertisement

loading