Page 1
ION GENERATOR OPERATION MANUAL “Plasmacluster” and “Device of a cluster of grapes” are trademarks of Sharp Corporation. * The number in this technology mark indicates an approximate number of ions supplied into air of 1 cm , which is measured around the center of a room applicable floor area (at 1.2 m height...
Page 2
Thank you for purchasing this Plasmacluster ion generator. Please read this manual carefully before using the product. Please be sure to read “IMPORTANT SAFETY INSTRUCTIONS” before using the product. This manual should be kept in a safe place for future reference. IG-EX20B_EN(Singapore).indd 2020/07/22 11:58:41...
CONTENTS IMPORTANT SAFETY INSTRUCTIONS ....2 PART NAMES ............4 PREPARATION BEFORE USE ....... 6 OPERATION ............8 CARE AND MAINTENANCE / REPLACEMENT ..9 TROUBLESHOOTING ..........14 SPECIFICATIONS ............ 16 IG-EX20B_EN(Singapore).indd 2020/07/22 11:58:41...
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Center or similarly qualified persons in order to avoid a hazard. Contact the nearest Service Center for any problems, adjustments or repairs.
Page 5
To prevent an accident or injury CAUTION such as electric shock and fire • Unplug the USB cable when not in use. Also, when plugging and unplugging the USB cable, hold the USB cable plug. (Otherwise, electric shock, electric leakage, or fire due to insulation deterioration is generated.) •...
PART NAMES Top / Control panel / Indication “LOW”, ”MED” operation light (Blue) “FULL POWER” operation light (Purple) Operation button Filter clean light (Orange) Filter reset button Unit replacing light (Red) Power button (Louver) Air outlet Plasmaclueter ion sign (Blue) Main unit IG-EX20B_EN(Singapore).indd 2020/07/22...
Page 7
Bottom / Side / Back Wall hook hole Air inlet Stand mounting hole Filter Plasmacluster Ion Unit holder Generating Unit * Bottom cover Unit cleaning brush * Stand Power supply input terminal (The inside of the bottom cover) USB connection terminal USB cable * 1 Unit means Plasmacluster Ion Generating Unit.
PREPARATION BEFORE USE Precautions on installation Please observe the following: • Be sure to place the product on a stable flat surface. • When installing the product on the wall, hang the product on a firmly fixed hook. Use a hook with a screw head diameter of 5 mm to 7 mm.
Page 9
Attaching the stand How to place the product • • When used in place When hanging on the wall • It is even more effective to use the air outlet toward a place where odors are a concern. When you use to defeat the product, lay a rug slip under the product to fix the...
OPERATION Operation Start / Stop Operation Start Stop Press (Power button raised) Press (Power button down state) Blue light is emitted • The product restarts operation in the previously selected mode. Operation switching If you want to operate the product quietly Reduce the operation sound and (Blue) release high-density...
CARE AND MAINTENANCE / REPLACEMENT 1 Filter clean light / Unit replacing light Filter clean light Filter clean light will be lit after approx. 1 month (approx. 720 hours), when operated 24 hours a day. Once cleaning is completed, then press and hold in the Filter reset button for Press for 3 at least 3 sec.
Page 12
CARE AND MAINTENANCE / REPLACEMENT 2 Filter (Air inlet) About once a month 1 Unplug the USB cable 2 Vacuum the dust from the air inlet with a vacuum cleaner Remove the bottom cover Coin 1 Remove the filter • Do not over-press the 2 Remove dust with a vacuum filter with the suction...
Page 13
Attach the bottom cover Coin (2 places) To maintain the ion concentration, clean the filter frequently even if the Filter clean light is not lit. After cleaning, press the Filter reset button for 3 seconds or more. • Do not turn on the product while the bottom cover is NOTE open.
Page 14
CARE AND MAINTENANCE / REPLACEMENT 3 Plasmacluster Ion Generating Unit About once every 6 months (electrode section) 1 Remove the bottom cover. (Page 10) 2 Pull out the unit holder. Unit holder Remove the dust attached to the electrode section of the unit with an included unit cleaning brush or commercially-available cotton applicator.
Page 15
How to replace the Plasmacluster Ion Generating Unit 1 Remove the unit holder from the main unit. (Page 12) 2 Replace with a new unit. Old unit New unit Replacement Plasmacluster Ion Generating Unit (1 unit) Model: IZ-C75CE • Replacement period: approx. 2 years after opening When caring for the unit NOTE •...
TROUBLESHOOTING Does the Plasmacluster Ion Generating Unit need to be replaced regularly? • The Plasmacluster Ion Generating Unit must be replaced regularly in order to maintain the ion density. The Plasmacluster Ion Generator does not work. • Is the Power button in the state of OFF? (Page 8) •...
Page 17
Unit replacing light (red) is flashing rapidly, and operation is stopped. • It is over the usage period of Plasmacluster Ion Generating Unit. Replace with new one. (Page 9, 13) Operation lights (“LOW”, “MED” and “FULL POWER”) are flashing simultaneously, and operation is stopped. Plasmacluster Ions are not released.
SPECIFICATIONS Model IG-EX20B Voltage USB cable * Rated input DC5V / 1A Applicable floor Approx. 1.8 m × 0.9 m area* Operation mode FULL POWER Approx. Approx. Approx. Air volume 0.05 m /min 0.06 m /min 0.08 m /min Power consumption 2.1 W...