Table 41. Memory configuration details (continued)
Memory Frequency
Custom Refresh Enable
Page Policy
Memory Training
Memory Boot Health
Check
Memory Timings Override
Memory Map
Memory RAS Configuration
Memory RAS Configuration
Setup
Pmem Configuration
Memory Dfx Configuration
BSSA Configuration Menu
CMI Init Configuration

IIO configuration

See the table below for the descriptions of options in IIO Configuration screen:
Table 42. IIO configuration details
Item
Socket0 Configuration
Socket1 Configuration
IOAT Configuration
PCIE OPROM Slot Options
Intel VT for Directed I/O (VT-d)
Intel® VMD technology
Intel® AIC Retimer/AIC SSD
Technology (non-VMD)
Auto/1200/1333/1400/1600/1800/
18660/2000/2133/2200/2400/2600/
2666/2800/2933/3000/3200/3400-
OvrClk/3466-OvrClk/3600-OvrClk/
3733-OvrClk/3800-OvrClk/4000-
OvrClk/4200-OvrClk/4266-OvrClk/
4400-OvrClk/4800-OvrClk
Disable/Enable
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Option
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Select maximum memory frequency in Mhz. If
Enforce POR option is disabled, user will be
able to run at higher frequencies than the
memory support (limited by processor
support). Do not select Reserved.
Enable/Disable a custom memory refresh
rate.
Set memory page policy parameters.
Set DDR4 training options.
Check whether the restored memory margin
offsets are within warning\critical limits.
Select the XMP profile to use.
Set memory mapping settings.
Display and provide options to change the
Memory RAS Settings.
-
Display and provide options to change the
PMem settings.
Display and provide options to change the
memory Dfx settings.
Set configuration options for the BSSA tool.
Help to configure CMI Init.
Description
-
-
Display and set all IOAT configuration options.
Display and set PCIE OPROM slot options.
Press Enter to bring up the Intel® VT for Directed I/O
(VT-d) Configuration menu.
Press Enter to bring up the Intel® VMD for Volume
Management Device Configuration menu.
Press Enter to bring up the Intel® AIC Retimer/AIC SSD
configuration menu.
.
129
Chapter 5
BIOS setup

Hide quick links:

Advertisement

Table of Contents
loading