Display Description; Measuring Modes; Real Time; Peak - PCE Health and Fitness CTT Series User Manual

Torque meter
Table of Contents

Advertisement

4.2

Display description

No.
Description
1
Limit value alarm for clockwise direction of rotation
2
Limit value alarm for counterclockwise direction of rotation
3
Measuring direction
4
Measuring mode
5
Last peak value in PEAK mode
6
Unit
7
Measured value
8
Connected to a PC
9
Set minimum limit value
10
Set maximum limit value
5

Measuring modes

This torque meter has four different measuring modes. If the measured value is outside the
measurement range, "OVER" is shown on the display and an acoustic signal is generated. Only
when the measured value is back within the measurement range, a normal measurement can be
resumed.
To switch between the modes, press the "MODE" key in the current measuring mode. The current
measuring mode is displayed below the measured value.
5.1

Real Time

In Real Time (RT) measuring mode, the current measured value is continuously displayed.
5.2

Peak

In peak mode (PK), the highest measured value is displayed and held. This measuring mode can
be used for tensile and compressive force. The peak value can be reset with the "Zero" key.
© PCE Instruments
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ctt 2Ctt 5Ctt 10

Table of Contents