6

Stopping and Starting the Pump

Starting the Pump
1. Be sure the pump is powered on and the green
power LED is on.
2. Select one of the speed buttons, then press the
Start/Stop button (LED on) to start the pump. The
pump will go into priming mode if priming feature
is enabled.
Stopping the Pump
1. Press Start/Stop to stop the pump.
When servicing equipment (filters, heaters, chlorinators
etc.), disconnect the communication cable, and switch
OFF circuit breaker to remove power from the pump.
Note: The pump can automatically restart if the
communication cable is connected.
Adjusting and Saving a Pump Speed
1.
While the pump is running, press the Up or Down
arrow to adjust to desired speed setting.
2.
Press and hold down a Speed button (1-4) for three
(3) seconds to save speed to the button or press
Save to save the speed.

Operating the Pump at Preset Speeds

The pump is programmed with four default speeds of
750, 1500, 2350 and 3110 RPM. Speed buttons 1-4 are
for each of the preset speeds as shown below.
1. Be sure the pump is powered on and the green
power LED is on.
2. Press the Speed button (1- 4) corresponding to
the desired preset speed and release quickly. The
LED above the button will turn on.
3. Press Start/Stop. The pump will quickly change to
the selected preset speed.
LED lit
1
2

Pump Operating Modes

®
The IntelliFlo
2 VST Variable Speed Pump can be
programmed in three different modes:
Manual, Schedule, and Egg Timer.
Speeds 1-4 can be programmed in all three modes.
Speeds 5-8 can only be programmed in Schedule mode
since there are no buttons on the control panel for Speeds
5-8. The default setting for Speeds 5-8 is "Disabled".
INTELLIFLO
®
2 VST Variable Speed Pump Installation and User's Guide
3
4
Manual
Speed 1 (1-4)
Schedule
Egg Timer
Disabled
Speed 5 (5-8)
Schedule
Speed Menu Tree Options
Manual
Assigns a speed to one of the four Speed buttons
on the control panel. This mode can only be used
for speeds 1-4. Speeds 1 and 2 are Manual by
default.
To operate in Manual mode, press one of the four
speed buttons and then press the Start/Stop
button. The pump will run the assigned speed for
that speed button.
Egg Timer
Speeds 1-4 can be programmed to run at a certain
speed and for a duration of time once a speed
button is pressed.
Speeds 3 and 4 are Egg Timers by default. This
prevents the pump from running at a speed higher
than half of the maximum speed indefinitely. If
you desire a different method of operation, speeds
3 and 4 can be changed to Manual mode in the
control menu.
To operate in Egg Timer mode, press a speed
button and then press Start/Stop. The pump will
run that speed for the set amount of time and then
turn off.
Schedule
Program speeds 1-8 start and stop at a specific
time during a 24 hour period. Speeds programmed
in Schedule mode will override any manually
selected speed once the next Schedule command
commences.
Set Speed - Defa
Set Speed
Set Start Time
Set Stop Time
Set Speed
Time
Default: Disabled
Set Speed
Set Start Time
Set Stop Time

Hide quick links: