T rou b l es h ooting
Oth ers
T rou b l e
●If any nuts in a connection are loose, firmly tighten them with a tool such as a monkey wrench.
W ater is l eak ing f rom th e
→ If the water leak does not stop, close the shutoff valve and consult with TOTO customer
pl u m b ing c onnec tions
service (see contact information on the back cover).
●The display goes out when no button on the remote control is pressed for about 60 seconds or
T h e d is pl ay on th e rem ote
c ontrol g oes ou t
more.
Y ou are not s u re if
●Since this product does not include the "Air deodorizer" function, it cannot be set even if you
th e A ir d eod oriz er
operate the remote control.
h as b een s et or not
●The water in the bowl unit that is used to mask the smell of excrement is the cause of the
W ater s pl as h es
u p w h en u s ing th e
splashing.
→ Adding a layer of toilet paper on the surface of the water can slightly dampen splashing.
toil et
W h en flushing, y ou
●There are cases when the sound is made inside the discharge pipe because of the device to
h ear a s q u is h ing
ensure water in the bowl unit after the unit flushes.
s ou nd u nd erneath
the floor
When flushing, You
●When the toilet is flushed together with waste material, the sound is a result of air, waste
h ear a g u r g l in g
material and water being pulled through the system.
s o u n d
T h ere are b l ac k
●Ammonia in urine may cause black stains.
s tain on or arou nd
→ If urine has splashed on the bowl unit or floor, wipe it immediately.
th e b ow l u nit
T h ere is b l ac k or
●It is a result of growth of airborne fungal spores or bacteria that feed on filth on the toilet bowl.
pink s l im e on th e
→ Clean with (non-abrasive) neutral toilet cleaner.
toil et b ow l s u rf ac e
●Condensation occurs when the humidity is high, and there is a significant difference between
T h ere are w ater
water and room temperatures.
→ Wipe off droplets with dry cloth.
d ropl ets on th e
(Condensation can build up on condensation-proof bowls when the difference between room
b ow l u nit s u rf ac e
and water temperatures exceeds 15°C and the ambient humidity levels reach 80%.)
72
P l eas e c h ec k
R ef . P ag e
Specifications
Item
Rated power supply
Rated current
Rated power consumption
-
Maximum power consumption
Type of water heater
-
Power cord length
Water protection level
Flush volume
-
Water supply system
Bowl
Flush type
Unit
Bowl style
Anti
Dynamic
-
freezing
mode
Spray
volume
-
Cleansing
Water temperature
Heater capacity
Safety device
Backflow prevention device
-
Surface temperature
Top
Heated
Unit
Heater capacity
seat
-
Safety device
Method
Airflow volume
Deodorizer
Power consumption
-
Warm air temperature
Airflow volume
Warm
air dryer
Heater capacity
Safety device
-
Water supply pressure
Water supply temperature
Working ambient temperature
Dimensions
Weight
*1 The flush volume changes depending on water pressure. *2 Temperature around the warm air outlet measured by TOTO.
●
When disposing of this product, please follow your local or state guidelines for proper disposal.
NX1, NX2
AC 220-240 V, 50/60 Hz
3.9-4.2 A
835-845 W
1458 W <when the temperature of the water supply is 0°C>
Instantaneous type
1.2 m (For Singapore, 5.0 m)
Full 3.8 L, Light 3.0 L
Direct supply, Pressurized supply
Cyclone flushing
Elongated
Flush volume (dynamic)
41 L/h
Rear cleansing
Approx. 0.32 to 0.43 L/min <at 0.2 MPa water pressure>
Rear soft cleansing
Approx. 0.32 to 0.43 L/min <at 0.2 MPa water pressure>
Front cleansing
Approx. 0.29 to 0.43 L/min <at 0.2 MPa water pressure>
Wide front cleansing
Approx. 0.35 to 0.43 L/min <at 0.2 MPa water pressure>
Adjustable temperature range: OFF, about 30°C to 40°C
1200-1428 W
Temperature fuse
Vacuum breaker, check valve
Adjustable temperature range: OFF, about. 28°C to 36°C
<With auto energy saver+ in operation: OFF>
560-670 W
Temperature fuse
O
deodorization
2
3
Normal mode: approx. 0.09 m
/min, Power mode: approx. 0.16 m
Normal mode: approx. 1.7 W, Power mode: approx. 5.3 W
*2
Adjustable temperature range: about 37°C to 55°C
Approx. 0.29m
200-238 W
Temperature fuse
Minimum required water pressure: 0.05 MPa <Dynamic, 10 L/min>,
(For Australia, 0.20 MPa <Dynamic, 10 L/min>)
Maximum water pressure: 0.75 MPa <Static>
0-35°C
0-40°C
W 468 mm x D 800 mm x H 565 mm
About. 61 kg
IPX4
*1
3
/min
3
/min
73