Advanced control panel
Hide thumbs Also See for 3008:

Advertisement

2070005
System error
2080001
System error
2080006
System error
2080008
System error
2080208
System error
Burner temp
3000007
sensor
3010007
Air temp sensor
3010202
Air overheat
Water temp
3020007
sensor
3020202
Water overheat
50001
System error
50006
System error
50008
System error
7020B
Low voltage
7020C
System error
System error
7020D
7020E
System error
Burner temperature is missing/invalid
Air temperature is missing/invalid
Air temperature is too high
Water temperature is missing/invalid
Water temperature is too high
CAN bus other errors
CAN bus timeout error
CAN bus busy error
Cannot start, low voltage
Cannot start, device locked
Cannot start, enable input not asserted
Cannot start, burner temperature
missing or too high
- 18 -
Contact service
Contact service
Contact service
Contact service
Contact service
Contact service
Connect air temperature sensor.
Check air vent´s and warm air hoses for
blockages.
Contact service
Water is not circulate, bleed the air out of
the system, check the waterpump.
Contact service
Contact service
Contact service
Renew/charge the battery
Open locking mode from the control
panel, check control panel user manual.
Enable wire is missing, connect the
enable wire or set the main power ON
Powercut during the operation, Wait that
unit cools down and try to start again.