Q-tran QTM-DRIVE Manual page 3

Led power supply 60w–200w
Hide thumbs Also See for QTM-DRIVE:
Table of Contents

Advertisement

QTM-DRIVE
DMX in/LedSync out
Use these connectors when the driver is used in a DMX network. For DMX in, connect the network cable's DMX+, DMX-
and DMX shielding wire (the orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in
shield connector respectively. ForLedSync out, connect the network cable's DMX+, DMX- and DMX shielding wire to the
LedSync out+, LedSync out- and LedSync shield connector respectively.
DALI
Use these connectors to connect the driver to a DALI network. Always combine a DA+ and DA- connector for either data
input or data output. A separate DALI power supply is required to power the DALI bus.
Wiring Diagram
DMX in +
DMX in -
DMX in shield
LedSync out +
LedSync out -
LedSync out shield
_
+
M
Ext in +
Ext in -
DA
DA
~
~
INPUT
Voltage: 120 - 277 VAC, 50/60Hz
Current, max per driver:
1.05A at 120V/60Hz
0.5A at 230V/50Hz
0.45A at 277V/60Hz
OUTPUT
Power per driver: 100W max
Voltage: 12V/24V output
Current
RGBW @ 12V: 1.25A per output
RGBW @ 24V: 1A per output
Output
RGB @ 12V: 1.66A per output
RGB @ 24V: 1.33A per output
Current max: 5A common anode
© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | sales@q-tran.com | www.q-tran.com
LED POWER SUPPLY 60W–200W
R
G
Common anode
R
R
12V / 24V DIP switch
-
+
-
NOTE
+
120-277
L
VAC
N
B
W
R
R
1
2
DALI
ENVIRONMENTAL
Ta operating range : -40°F ~ +122°F
Tc max : 185°F
Lifetime : 50K hours at 122°F
MTBF : 480,000 hours
COMPLIANCE / SAFETY
Class 2 output.
Class A sound rating
FCC: Title 47CFR Part 15 Class B
The wiring inside electrical enclosures shall comply with the
600V/105 ºC or higher.
CSA certified
: UL-2108
: UL-8750
: CSA C22.2 No 250.0-08
: CSA C22.2 No 250.13-14
NOTE: All measurements have been carried out at maximum load in free air without heat sink.
LED wire length:
Maximum wire length
from LED driver to LED engine at full load:
AWG value
Distance (ft)
NOTE: Longer wire lengths increase EMI susceptibility.
AWG 20-16
1
0.5-1.5 mm
2
2
9 mm
0.35 inch
Pay attention when connecting the LED groups:
polarity reversal results in no light output and often damages
the LEDs
combining + and - of different groups
damages the driver
Specification subject to change. Rev-11-19-20
20
18
16
46
72
118
AWG 24-16
0.2-1.5 mm
2
9 mm
0.35 inch

Advertisement