IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Display
Mechanical strength
Contamination level
Overvoltage category
4.4
Standards
4.4.1
Standards used
4.4.2
CE Marking
Declaration of Conformity
In operation
Max. vibration:
Frequency range:
10...150 Hz
Excursion: 0.075 mm from 10
Hz to 57 Hz
Acceleration: 1 g at 57 Hz to
150 Hz
Acc. to EN 600068-2-6
2
2
Tab. 4-5:
Ambient conditions
The system components of the Operator Display correspond to the following
standards:
Standard
EN 60 204-1
EN 61 000-6-4
EN 61 000-6-2
EN 61 558-2-6
EN 60 664-1
EN 61 131-2
EN 61 131-2
ISO 13 850
EN 60 529
EN 60 068-2-6
EN 60 068-2-27
EN 60 721-3-1 and
EN 60 721-3-3
Tab. 4-6:
Standards used
Transport
Max. shock:
15 g 11 ms
Acc. to EN 60068-2-27,
No malfunction
2
–
Description
Safety of machinery - Electrical
equipment of machines
Generic standards - Emission standard
(industrial environments)
Generic standards – Noise immunity
(industrial environments)
Transformer for 24 V power supply unit,
safe separation
Overvoltage category II
24 V output requirements
24 V current supply requirements
Safety of machinery, E-STOP devices
Degrees of protection (including housings
and installation compartments)
Vibration test
Shock test
Climatic class
R911323862_Edition 07 Bosch Rexroth AG
13/57
Technical data
Storage
Max. shock:
15 g 11 ms
Acc. to EN 60068-2-27,
No malfunction
2
–