5
Maintenance & repairs
Under clean operating conditions, the valve does not require any maintenance during the specified cycle life.
Contamination from the process may influence the function and requires more frequent maintenance.
Before carrying out any maintenance or repairs, please contact VAT. It has to be individually decided whether the
maintenance/repair can be performed by the customer or has to be carried out by VAT. The fabrication number on the
valve
made in Switzerland
Fabrication No.:
patented
. . . . . – . . . . – . . . . / . . . .
A – . . . . . .
has always to be specified.
All supplies (e. g. compressed air, electrical power) must be disconnected for removal/installation of the valve from/into
the system and for maintenance work.
Even with disconnected supply, loaded springs and/or air cushions in cylinders can be potential hazards.
Keep fingers and objects away from the valve opening!
Products returned to VAT must be free of harmful substances such as e.g. toxical, caustic or microbiological ones. If
products are radioactively contaminated, fill in the VAT form «Contamination and Radiation Report» and send it with the
product. The form is available at VAT. The maximum values indicated in the form must not be exceeded.
5.1

Replacement of Seals

The item numbers in brackets refer to the drawing on page 9
Remove power connector and signal connector
Remove screw 27, coil assembly 26 and O-Ring 18
Remove 4 bonnet screws, remove bonnet flange 16
Withdraw axial conduit 17 with first O-Ring 62
Withdraw complete valve insert from body
Remove second O-ring 62
Stick a needle into the O-ring 61 and pull it out of groove
Attention: Do not damage the sealing surface!
Clean all sealing surfaces and contaminated parts
Put new O-ring 61 on plate groove and press it crosswise into groove at 4 points
Press O-ring 61 uniformly into groove
Put new bonnet seal (O-ring, 62) into body
Insert complete valve insert with bellows into body.
Insert O-Ring 62 and axial conduit 17
Insert bonnet flange 16 carefully. Do not cant!
Fasten 4 bonnet screws uniformly and crosswise in 2 to 3 steps
Attach O-Ring 18 and coil assembly 26
Fasten screw 27
Attach power connector and signal connector.
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com