Parker R4V Series Translation Of Original Operating Instructions

Parker R4V Series Translation Of Original Operating Instructions

Pilot operated pressure relief valve subplate mounted and 2-way cartridge
Hide thumbs Also See for R4V Series:

Advertisement

Quick Links

Bulletin MSG11-5715-661/UK
Operating instructions
Series R4V*V* / R4V*W*
Series R6V*V* / R6V*W*
Series DSDU*1078 E*E TÜV
Translation of German original operating instructions
Series R4V and R6V
Pilot operated pressure relief valve
Subplate mounted
Series DSDU
Pilot operated pressure relief valve
2-way cartridge valves
Parker Hannifin
Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.: (+49) 181 99 44 43 0
E-mail: valvesisde@parker.com
Copyright © 2019, Parker Hannifin Corp.

Advertisement

Table of Contents
loading

Summary of Contents for Parker R4V Series

  • Page 1 Pilot operated pressure relief valve 2-way cartridge valves Parker Hannifin Manufacturing Germany GmbH & Co. KG Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com Copyright © 2019, Parker Hannifin Corp.
  • Page 2 The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
  • Page 3: Table Of Contents

    Dimensions series DSDU*E* Mounting Surface Technical data series DR4V*V* / R4V*W* / R6V*V* / R6V*W* Dimensions series R4V* without vent function Dimensions series R6V* without vent function Dimensions series R6V* with vent function R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 4: Basic Information

    Any result conformity loss or damage is not the responsibility • Attestation for product acceptance of Parker Hannifin. • Certificate for product acceptance If the described product is installed in a machine that came into circulation before...
  • Page 5: Electronic Control System

    30 V in order to ensure the solenoid is cor- rectly energised. For this reason, choose solenoids with lower voltages! A suitable tool must be used for manual emergency actuation of the solenoid. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 6: Venting Of Hydraulic System

    "General notes on safety" demonstrably unable to ensure that the – before starting work. This specifically product is used as specified. applies to personnel who will only work with the product occasionally (e.g. setting up, maintenance). R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 7: Limits Of Use

    That is why the plugs must be checked for leaks at the regular maintenance interval. Leaking plugs may constitute a safety hazard, so the valve must be returned to the manufacturer for repair. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 8: Correct Use

    Series DSDU* The system pressure in port A is applied via an As Parker has no influence on the state aperture in the main cone to the spring loaded the product arrives in, please check for cone in the pilot head.
  • Page 9: Storage

    If the safety devices or sealing surfaces are damaged or are missing individual parts with relevance to the product's function, the product may not be used. Remove all transport securing devices, protective covers and packaging. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 10: Installation Instructions Dsdu

    • parts of the machine and individually installed components must be adequately earthed, • all limit switches and control elements must be properly integrated with the control system. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 11 – if necessary improve filtering and replace the medium Actuate the valve periodically Broken spring Return the valve to the manu- facturer for inspection Pilot oil discharge interrupted Check pilot oil discharge and delivery R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 12: Modification

    Note also the information in sections 1. "Warranty "Personnel requirements" and 3. "Remaining risk". and liability", 2. "Use of operating instructions", "Compliance with other rules and instructions", "Personnel requirements" and 3. "Remaining risk". R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 13: Other Documentation

    - Part 4: Pilot-operated safety • AD-2000-Regelwerk W3/2:2015-11 valves Spheroidal-graphite cast iron, non-alloy and • DIN EN 60204-1:2007-06; VDE 0113-1:2007- low alloy Safety of machinery – Electrical equipment of machines – Part 1: General requirements R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 14: Declaration Of Conformity

    41564 Kaarst, Deutschland Mr Günther Funk is authorised to compile the technical file. For enquiries, see the company address. Parker Hannifin Manufacturing Germany GmbH & Co. KG declares that the safety valves Type R4V*V and R4V*W Type R6V*V and R6V*W Type DSDU 578 P20E TÜV and DSDU 1078 E*E TÜV...
  • Page 15: Technical Data

    * Width 65 mm Installa- tion BK414 4x M8x40 ISO 4762-12.9 31,8 Nm SK-DSDU10E16 SK-DSDU10E16V Mounting BK391 4x M12x50 ISO 4762-12.9 108 Nm SK-DSDU10E25 SK-DSDU10E25V BK415 4x M16x55 ISO 4762-12.9 264 Nm SK-DSDU10E32 SK-DSDU10E32V R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 16: Mounting Surface

    H13 m1±0.2 m2±0.2 m3±0.2 25.5 M 12 M 16 m4±0.2 t1+0.1 t2+0.1 t4 max* 10.5 29.5 0.03 0.05 40.5 0.03 0.05 48.0 0.03 * only with d4 and t4 R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 17: Technical Data Series Dr4V*V* / R4V*W* / R6V*V* / R6V*W

    12 V = 24 V = ±10 ±10 Supply tolerance Power consumption hold 32.7 in rush 32.7 Connector Connector to EN 175301-803 Wiring min. ] 3 x 1.5 recommended Wiring length max. [m] 50 recommended R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 18: Dimensions Series R4V* Without Vent Function

    10.8 Surface finish BK505 4x M10x35 ISO 4762-12.9 63 Nm ±15% S26-58507-0 S26-58507-5 BK485 4x M10x45 ISO 4762-12.9 63 Nm ±15% S26-58475-0 S26-58475-5 BK506 6x M10x45 ISO 4762-12.9 63 Nm ±15% S26-58508-0 S26-58508-5 R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 19: Dimensions Series R6V* Without Vent Function

    141 148,3 – 46.5 ISO-Code d1max d2max 6264-08-13-*-97 23.4 17.5 6264-10-17-*-97 Surface finish BK366 4x M16x70 ISO 4762-12.9 264 Nm ±15% S26-96396-0 S26-96396-5 BK507 4x M18x75 ISO 4762-12.9 398 Nm ±15% S26-96392-0 S26-96392-5 R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
  • Page 20: Dimensions Series R6V* With Vent Function

    153 163.8 141 – 36.5 ISO-Code d1max d2max 6264-08-13-*-97 23.4 17.5 6264-10-17-*-97 Surface finish BK366 4x M16x70 ISO 4762-12.9 264 Nm ±15% S26-96396-0 S26-96396-5 BK507 4x M18x75 ISO 4762-12.9 398 Nm ±15% S26-96392-0 S26-96392-5 R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...

Table of Contents