Page 2
The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
Dimensions series DSDU*E* Mounting Surface Technical data series DR4V*V* / R4V*W* / R6V*V* / R6V*W* Dimensions series R4V* without vent function Dimensions series R6V* without vent function Dimensions series R6V* with vent function R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
Any result conformity loss or damage is not the responsibility • Attestation for product acceptance of Parker Hannifin. • Certificate for product acceptance If the described product is installed in a machine that came into circulation before...
30 V in order to ensure the solenoid is cor- rectly energised. For this reason, choose solenoids with lower voltages! A suitable tool must be used for manual emergency actuation of the solenoid. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
"General notes on safety" demonstrably unable to ensure that the – before starting work. This specifically product is used as specified. applies to personnel who will only work with the product occasionally (e.g. setting up, maintenance). R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
That is why the plugs must be checked for leaks at the regular maintenance interval. Leaking plugs may constitute a safety hazard, so the valve must be returned to the manufacturer for repair. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
Series DSDU* The system pressure in port A is applied via an As Parker has no influence on the state aperture in the main cone to the spring loaded the product arrives in, please check for cone in the pilot head.
If the safety devices or sealing surfaces are damaged or are missing individual parts with relevance to the product's function, the product may not be used. Remove all transport securing devices, protective covers and packaging. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
• parts of the machine and individually installed components must be adequately earthed, • all limit switches and control elements must be properly integrated with the control system. R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
Page 11
– if necessary improve filtering and replace the medium Actuate the valve periodically Broken spring Return the valve to the manu- facturer for inspection Pilot oil discharge interrupted Check pilot oil discharge and delivery R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
Note also the information in sections 1. "Warranty "Personnel requirements" and 3. "Remaining risk". and liability", 2. "Use of operating instructions", "Compliance with other rules and instructions", "Personnel requirements" and 3. "Remaining risk". R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...
41564 Kaarst, Deutschland Mr Günther Funk is authorised to compile the technical file. For enquiries, see the company address. Parker Hannifin Manufacturing Germany GmbH & Co. KG declares that the safety valves Type R4V*V and R4V*W Type R6V*V and R6V*W Type DSDU 578 P20E TÜV and DSDU 1078 E*E TÜV...
12 V = 24 V = ±10 ±10 Supply tolerance Power consumption hold 32.7 in rush 32.7 Connector Connector to EN 175301-803 Wiring min. ] 3 x 1.5 recommended Wiring length max. [m] 50 recommended R_V-DSDU 5715-661 UK.indd 11.12.19 Parker Hannifin Corporation...