Optional Units - Omron SYSDRIVE 3G3XV-EV2 Series Operation Manual

Table of Contents

Advertisement

Specifications
Inverter Model 3G3XV-jjjjj-EV2
Operation
Input
conditions
di i
signals
i
l
Output
signals
Built-in functions
Monitor
display
function
Protective configuration
Cooling method
Weight in lb (kg)
Environmen-
Location
tal Conditions Ambient temperature
l C
di i
Storage temperature
Humidity
Vibration

1-6-3 Optional Units

Name
Braking Resistor Unit
Braking Resistor
Note
24
Operation signal
Reset
Multifunction input
selection
Operation state
(photo-coupler out-
put)
Fault contact
Digital Operator
Analog output mon-
itor
2
Note
1. Use a standard 4-pole motor for maximum applicable motor
output.
2. Temperature during shipping (for short period).
Model (code no.)
3G3IV-PLKEBjjjj
3G3IV-PERF150WJjjj
When using the Braking Resistor Unit or Braking Resistor, set the
stall prevention during deceleration (n% 20) to "1" (disabled).
A4002
A4004
A4007
Forward operation/reverse operation by individual command
Releases protection while the function is operating.
Multifunction contact input: two of the following signals avail-
able to select.
External fault multispeed command, jog operation, accel/
decel time select, 3-wire sequence, external coasting stop,
speed search command.
Multifunction contact output: two of the following signals
available to select.
During running output, zero speed, frequency agree, output
frequency
setting value, during overtorque detection
NO/NC contact output
The following set-up is available: frequency reference bias/
gain, upper/lower frequency limit, DC braking stop current at
start, torque boost, frequency meter calibrating gain, fre-
quency jump, S-curve characteristics, auto reset/restart
operation.
Displays setting frequency, output frequency, output current,
rotating direction, and the contents at protective function
operation.
Analog output (0 to 10 VDC). Possible to select output fre-
quency or output current.
Enclosed wall-mounted type NEMA 1
(An open chassis type is also available.)
Self-cooling
4.4 (2)
6.6 (3)
Indoor (protected from corrosive gases and dust)
+14 to 104 F (–10 to +40 C) (not frozen)
–4 to 140 F (–20 to +60 C)
90% RH (without condensation)
2
Up to 9.8 m/s
(1 g) at less than 20 Hz.
2
Up to 2 m/s
(0.2 g) at 20 to 50 Hz.
Function
Shortens the motor deceleration time
by causing the regenerative energy to
be consumed through the resistor.
Section 1-6
A4015
A4022
A4037
Forced cooling
11.0 (5)
Installing
position
Separately
installed

Hide quick links: