Equalising Charge - Fronius Selectiva 4.0 30 kW Operating Instructions Manual

Battery charging system
Hide thumbs Also See for Selectiva 4.0 30 kW:
Table of Contents

Advertisement

The following settings are available for temperature-controlled charging:
automatic/OFF/required
-
-
-
Error overtemperature ON/OFF
-
-
Warning overtemperature ON/OFF
-
-
An external temperature sensor is required for certain characteristics. If this type of char-
acteristic is selected in configuration mode, a note is shown indicating that an external
temperature sensor is required.
The following characteristics require an external temperature sensor:
-
-
Equalising

Equalising charge

charge
OFF
-
automatic ... Temperature-dependent adjustment of the charging characteristic.
OFF ... The measured battery temperature is not taken into account.
required ...
Charging only starts if the temperature sensor is connected.
ON ... Error message in the event of battery overtemperature.
Charging process stops and can only be continued once the battery has cooled
down and been reconnected.
OFF ... No error message in the event of battery overtemperature.
ON ... Warning in the event of battery overtemperature.
OFF ... No warning in the event of battery overtemperature.
28 - FCC IUI - CSM WET
30 - FCC IUI - WET
There is no equalising charge.
A note is displayed if a characteristic that
requires an external temperature sensor is
selected.
Use the "Pause/Start" key to confirm
1
the note.
41

Advertisement

Table of Contents
loading

Table of Contents