Data of the power cable on the stator

Table 5- 1
Data of the power cable on the stator
Motor type
Frame size
1FW6720-
410 x 75
2PB07-3Axx
1FW6720-
410 x 100
2PB10-2Exx
1FW6720-
410 x 100
2PB10-4Fxx
1FW6720-
410 x 125
2PB12-4Fxx
1FW6720-
410 x 150
2PB14-4Fxx
Relevant for retrofitting a connector
*)
5.2.2.2

Specifications for the signal cable on the stator

Table 5- 2
Specifications for the signal cable on the stator
Motor type
Frame size
1FW6720-
2PBxx-xxxx
Relevant for retrofitting a connector
*)
1FW6 external rotor built-in torque motors
Operating Instructions, 12/2020, A5E49196960B AB
Max. diameter
in mm
12.3
11
18.2
18.2
18.2
Max. diameter
in mm
All
11
No. of cores x
Min. bending
cross section
radius
in mm
in mm
2
4 x 4
49.2
4 x 2.5
44
4 x 10
72.8
4 x 10
72.8
4 x 10
72.8
No. of cores x
Min. bending
cross section
radius
in mm
in mm
2
6 x 0.5 + 1 x 1
50
Connection
5.2 Electrical connection
Max. height of
Required con-
sleeve
nector size
in mm
23
1.5
18
1
30
1.5
30
1.5
30
1.5
Max. height of
Required con-
sleeve
nector size
in mm
18
M17
*)
*)
73