4.2

Forces that occur between the stator and rotor

Figure 4-1
① Stator
② Rotor
F
a
F
r
Radial forces between the stator and rotor
The following table shows the active radial forces in N per 0.1 mm centering error between
the stator and rotor. The longer the active part, the greater the radial force.
Table 4- 1
Overall length in mm
Radial force
Note
It is imperative that you observe the radial forces between the stator and rotor as well as the
maximum permissible concentricity error. The maximum permissible concentricity error is
specified in the dimension drawing in the Configuration Manual "SIMOTICS T-1FW6 external
rotor built-in torque motors".
1FW6 external rotor built-in torque motors
Operating Instructions, 12/2020, A5E49196960B AB
Active forces when stators and rotors are joined
Axial force of attraction
Radial attractive force
Radial forces in N/0.1 mm with radial centering errors during installation
4.2 Forces that occur between the stator and rotor
75
100
800
1070
Installation
125
150
1270
1560