Error code/symptom
962
(Parallel port error)
998
(Automatic Restart or AC
power restored)
999
(System recovered from
backup BIOS)
11XX
(System board serial port 1 or
2 error)
1162
(Serial port configuration
conflict)
1301
(I2C cable to front panel not
found)
1302
(I2C cable from system board
to power on and reset
switches not found
1303
(I2C cable from system board
to power backplane not
found)
1304
(I2C cable to diagnostic LED
board not found)
1600
(Advanced System
Management processor is not
functioning)
1601
(Advanced System
Management flash update is
needed)
1762
(Fixed Disk Configuration
error)
FRU/action
1. Disconnect external cable on parallel port.
2. Run Configuration/Setup.
3. System board.
v No action required.
v Reflash BIOS code.
1. Disconnect external cable on serial port.
2. Run Configuration/Setup.
3. System board.
1. Disconnect external cable on serial port.
2. Run Configuration/Setup.
3. System board.
1. Cable
2. Front panel
3. Power switch assembly
4. System board
1. Cable
2. Power switch assembly
3. System board
1. Cable
2. Power backplane
3. System board
1. Power switch assembly
2. System board
1. Verify system-management processor jumpers are set correctly.
2. Disconnect computer from power source, wait 30 seconds, reconnect, and retry.
3. System board.
1. Flash update Advanced System Management processor.
2. System board.
1. Fixed disk drive.
2. Fixed disk cable.
3. Run Configuration/Setup.
4. Fixed disk adapter.
5. SCSI backplane.
6. System board.