Genius TRIGON 02 Manual For The Installer page 8

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
Page 
TRIGON 02 - TRIGON K
Guide for the installer
Thank you for choosing our product. GENIUS is sure that it will give
you all the performances you are looking for. All our products
are the result of a long experience in the field of the automated
systems, reinforced by the fact of being part of the world leading
group of this sector.
In the middle of the handbook you will find a detachable
brochure with the images for the installation.
These instructions apply to the following model:
TRIGON 02
The external automation with articulated arms automates resi-
dential swing-leaf gates with leaves of up to 3m in length, and
is ideal for applications on large pilasters without the need to
provide niches (sometimes required to observe the installation
dimensions of piston driven devices).
It consists of an irreversible electro-mechanical operator with
guard and an articulated-arm activation system to be fitted to
the gate with the appropriate accessories.
The irreversible system ensures the gate is mechanical locked
when the motor is not operating. No lock need be installed for
leaves up to 2m in length.
A manual release makes it possible to move the gate in the event
of a power-cut or fault.
IMPORTANT NOTES FOR INSTALLER
Before starting the installation of the operator read this manual
completely.
Keep this manual for future reference.
Smooth operation and specifications are obtained only declared
following the directions given in this handbook and with acces-
sories and safety devices GENIUS.
The lack of a mechanical clutch device requires to ensure an
adequate level of security automation, the use of a central
control device with an electronically controlled clutch.
The automation was designed and built to control vehicular
access. Avoid any other use.
The operator can not be used to handle emergency exit routes
or gates installed on emergency (escape routes).
If there is built-in anti motorize from a door to the walkway is
required to add a safety switch on the door, connected on the
entry of STOP , to inhibit the operation of automation with door
open.
Everything that is not expressly stated in this manual is not al-
lowed.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
With reference to Figure 1
Pos
Guard
a
Operator securing base-plate
b
Release wrench
c
Release
d
Gearmotor
e
Transmission shaft
f
Straight lever of articulated arm
g
Curved lever of articulated arm
h
Front coupling
i
TAB. 1 TECHNICAL SPECIFICATION OF OPERATOR
MODEL
Power supply
Power absorption
Current absorption
Max torque
Nominal Torque
Starting capacitor
Leaf max length
a
Thermal protection for winding
Reduction ratio
Angular velocity
Description
TRIGON 02 - TRIGON K
230V~
115V~
24 Vdc
50Hz
60Hz
280 W
40 W
300 W
1.2 A
2 A
2.8 A
250 Nm
200 Nm
250 Nm
170 Nm
140 Nm
170 Nm
8 µF
/
30 µF
3 m
140 °C
/
140 °C
1:700
8 °/sec
MODEL
Ambient temperature
Use frequency at 20°C
Cycles / hour at 20°C
Noise
Weight of gearmotor
Protection class
Gearmotor overall dimension
An electrolock should be installed in the event of leaves excee-
a
ding 2 metres, in order to guarantee the leaf blocking.
2. ELECTRICAL EQUIPMENT (standards system)
With reference to Figure 3
Pos.
Description
Operators
a
TX photocells
b
RX photocells
c
Key selector
d
Flashing lamp
e
Control unit
f
Mechanical stops
g
To lay electrical cables, use adequate rigid and/or flexible
tubes.
Always separate low voltage accessories from those ope-
rating at 230/115 V~. To avoid any interference, always use
separate sheaths.
For the motor cable to use a sheath suitable for outdoor use, a
hand that is piped in special ducts always external use.
3. INSTALLATION OF AUTOMATION
3.1. PRELIMINARY CHECKS
To ensure safety and an efficient automation, make sure
the following requirements are met:
The gate structure must be suitable for automation. In particular,
make sure it is sufficiently sturdy and rigid, and that its dimensions
are in line with those indicated in the technical specifications.
Make sure that the leaves move properly and uniformly, without
any irregular friction during their entire travel.
Check if hinges are in good condition.
Make sure the travel limit mechanical stops are present. We
advise you to carry out any metalwork jobs before installing
the automation.
3.2. INSTALLATION DIMENSIONS
Establish the installation position of the operator by consulting
Fig. 4-5-6.
INWARD OPENING (Fig. 5)
A (mm)
B (mm)
60 ÷ 110
110 ÷ 160
160 ÷ 210
110 ÷ 130
210 ÷ 260
260 ÷ 310
310 ÷ 360
60 ÷ 110
190 ÷ 210
110 ÷ 160
230 ÷ 250
160 ÷ 210
290 ÷ 310
210 ÷ 260
310 ÷ 330
As for 120° openings the curved arm must be fixed to the
hole marked with the letter "X"
TRIGON 02 - TRIGON K
-20 °C +55 °C
S3 - 30%
S3 - 100%
S3 - 30%
>30
>100
>30
<70 dB(A)
11.5 Kg
IP 44
Vedi Fig. 2
Cables
230 Vac
24 Vdc
115 Vac
4x1 mm
2x1.5mm
2
2x0.5 mm
2
4x0.5 mm
2
2x0.5 mm
2
2x1.5 mm
2
3x1.5 mm
(power supply)
2
a (°)
C max. (mm)
730
720
710
90
700
690
670
650
600
120
540
510
120
2