Genius JA574 Use And Installation Instructions

Genius JA574 Use And Installation Instructions

Microprocessor control unit for hinged gates

Advertisement

CENTRALE DI COMANDO A MICROPROCESSORE PER CANCELLI A BATTENTE
MICROPROCESSOR CONTROL UNIT FOR HINGED GATES
ARMOIRE DE COMMANDE À MICROPROCESSEUR POUR PORTAILS BATTANTS
CENTRAL DE MANDO CON MICROPROCESADOR PARA PORTONES DE TIPO BATIENTE
MIKROPROZESSOR-STEUEREINHEIT FÜR FLÜGELTORE
JA574
ISTRUZIONI PER L'USO – NORME DI INSTALLAZIONE
USE AND INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L'EMPLOI – NORMES D'INSTALLATION
INSTRUCCIONES PARA EL USO – NORMAS DE INSTALACIÓN
BETRIEBSANLEITUNG - INSTALLATIONSVORSCHRIFTEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JA574 and is the answer not in the manual?

Questions and answers

Summary of Contents for Genius JA574

  • Page 1 MICROPROCESSOR CONTROL UNIT FOR HINGED GATES ARMOIRE DE COMMANDE À MICROPROCESSEUR POUR PORTAILS BATTANTS CENTRAL DE MANDO CON MICROPROCESADOR PARA PORTONES DE TIPO BATIENTE MIKROPROZESSOR-STEUEREINHEIT FÜR FLÜGELTORE JA574 ISTRUZIONI PER L’USO – NORME DI INSTALLAZIONE USE AND INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L’EMPLOI – NORMES D’INSTALLATION INSTRUCCIONES PARA EL USO –...
  • Page 2 Normes indiquées au point 10. 6) GENIUS declines all liability caused by improper use or use other than that for 16) Les dispositifs de sécurité (norme EN 12978) permettent de protéger des which the automated system was intended.
  • Page 3 ENGLISH CONTROL BOARD JA574 WARNINGS LAYOUT AND COMPONENTS Important: Before attempting any work on the control board (connections, maintenance), always turn off power. - Install, upstream of the system, a differential thermal breaker 2 3 4 5 6 7 8 9 10 11 12 (Residual Current Device) with adequate tripping threshold.
  • Page 4 ENGLISH 4.1. Connection of photocells and safety devices Opening/closing safety devices: they operate during the gate Before connecting the photocells (or other devices) we advise opening and closing movements and, therefore, they you to select the type of operation according to the movement are suitable for the opening and closing areas against area they have to protect (see fig.3): the risk of impact.
  • Page 5 ENGLISH Connection of two pairs of closing photocells Connection of 1 pair of opening photocells 9 10 11 12 13 14 15 16 17 18 19 9 10 11 12 13 14 15 16 17 18 19 CL OP CL OP +24V OPEN +24V...
  • Page 6 M1. In the B and C logics, it always commands closing of both leaves. JA574 To install several partial opening pulse generators, connect the N.O. contacts in parallel (see fig. 13).
  • Page 7 ENGLISH 5. MICROSWITCH PROGRAMMING LEAF 1 FORCE LEAF 2 FORCE 1 (MIN) 1 (MIN) OPENING LEAF DELAY (s) 8 (MAX) 8 (MAX) CLOSING PHOTOCELL LOGIC REVERSES ON RELEASE REVERSES IMMEDIATELY 10 11 12 SW10 LOGIC PAUSE (s) FAIL SAFE CLOSING LEAF SW11 SW12 DELAY (s)
  • Page 8 ENGLISH 6. START-UP The procedure has ended and the gate is ready to operate. Next pulse closes leaves and they stop on automaticaly reaching 6.1. LED CHECK closed position. The table below shows the status of the LEDs in relation to to the - ADVANCED COMPLETE LEARNING: status of the inputs.
  • Page 9 ENGLISH...
  • Page 10 ENGLISH...
  • Page 11 “16”. 25) El usuario no debe por ningún motivo intentar reparar o modificar el producto, 18) GENIUS décline toute responsabilité quant à la sécurité et au bon debe siempre dirigirse a personal cualificado.
  • Page 12 Les descriptions et les illustrations du présent manuel sont 73/23 CEE y sucesiva modificación 93/68 CEE, sowie 93/68 EWG fournies à titre indicatif. GENIUS se réserve le droit d’apporter 89/336 CEE y sucesivas modificaciones 92/31 CEE y à tout moment les modifications qu’elle jugera utiles sur ce 93/68 CEE.