Parameter Description - Axminster SX2.7 Original Instructions Manual

Mill drill
Hide thumbs Also See for SX2.7:
Table of Contents

Advertisement

Tips: Please pay attention to the small icons on the buttons and understand the meaning
of the icons, which will make the operation of the digital display faster and easier.
Display Description
Error
Information description
message
E01
Parameter input error
E06
Sensor failure: 1: sensor damage; 2: sensor cable is damaged;
E07
Magnetic stripe detection failed: 1: no magnetic strip; 2: magnetic strip is damaged; 3: reading
head is too far away from the magnetic strip
E08
Battery is too low, it is recommended to replace the battery immediately
E09
The read head is too close to the tape
E10
The read head is too far from the tape
E12
No battery, no battery installed in the digital display
E20
The measured value is out of the display range

Parameter Description

Numbering
Function
description
Measurement
P01,P31,
unit switching
P61
Current
P02,P32,
setting or (via
P62
shortcut)
Measuring
P03,P33,
direction or (via
P63
shortcut)
Length
P04,P34,
resolution
P64
Scale factor
P06,P36,
P66
Concentric
P08,P38,
diameter
P68
Angle
P09,P39,
resolution
P69
Absolute/Relati
P10,P30,
ve mode
P60
Reset
P28,P58,
P88
Adaptive
P07,P37,
calibration
P67
via shortcuts)
Parameter
Length / Angle
value
-999999~~99999
9
0~1
0,1,2,3,4
0.00001~2.99999
0.01~9999.99
0.01 degree 0.01
points
0.05 points 0.1
points
1 degree
0:unlock
1:lock
None
GO
(or
Default
Parameter description
s
0
0:Length mode
1:Angle mode
0
Save the input value as the
current value
1
0 or 1 represents two
directions
4
0:INCH
2:0.1
4:0.01
1
Display value = measure
true value * scale factor
500.00
The diameter of the disc to
which the magnetic strip is
attached
0.01de
Sufficient
under
gree
mode
0
By releasing the
None
Restore
default
settings
GO
GO:Enter the state, slowly
move
(can
repeatedly) sensor, move
150MM
in
seconds,
jump to the current value
state after learning success
21
Remarks
After modification, press
"Enter" to confirm
Enter
before
1234
After modification, press
"Enter" to confirm
Change the direction of
the sensor and also
change the direction of
measurement
After modification, press
1:1
"Enter" to confirm
3:0.05
After modification, press
"Enter" to confirm
Diameter needs to add
magnetic strip thickness
1.5mm*2mm=3MM
angle
After modification, press
"Enter" to confirm
key
Shortpress
change mode
factory
Enter password before
recovery:1234
If the calibration is not
successful,
be
moved
adjust
between the sensor and
about
10
the magnetic stripe. It is
automatically
recommended
1~~2MM.
Repeat
again
the
password
modification:
key to
please
the
distance
to
be
the
operation

Advertisement

Table of Contents
loading

This manual is also suitable for:

107154

Table of Contents